Figure 1: location of the heartbeat switch – Allied Telesis AT-200 Series CentreCOM Benutzerhandbuch

Seite 9

Advertising
background image

2

When necessary, you can enable the SQE test using the Heartbeat switch located
on the Printed Circuit Board (PCB) inside the transceiver body. This must be done
without the tap body installed in the transceiver.

Checking and setting the SQE/Heartbeat switch

1.

If the tap body is not installed in the transceiver (for models AT-205 and
AT-206), skip to step 3.

2.

To remove the tap body from the transceiver, remove the two panhead
screws and slide the tap body out.

3.

Locate the PCB inside the tap body opening. See Figure 1. With the
transceiver facing you, the SQE/Heartbeat switch is on the right side of the
circuit board. Set the switch to the desired setting (“1” = SQE enabled;
“0” = SQE disabled).

4.

Install the tap body.

Figure 1:

Location of the Heartbeat Switch

Thick Ethernet installation with coaxial active tap assembly
(for model AT-206)

Before installing the AT-206 Single Port Transceiver, check to see that the
transceiver package contents are complete. If any of the following items are
missing or damaged, contact your sales representative.

AT-200 Series Single Port Transceiver

AT-06 tap kit

Clamp/pressure-block assembly

Tap body

Braid terminators (2)

Probe assembly

Protective dust cover

Button head socket screw

Manual

Warranty card

Panhead screw (2)

Transceiver
body

Tap body opening