Spektrum SPMAR12110 Benutzerhandbuch

Seite 22

Advertising
background image

EN

22

Problem

Possible Cause

Solution

Aircraft does not

function after

connecting flight

battery and aircraft

smells burnt

User may have acciden-

tally plugged the flight

battery in with the wrong

polarity

Replace AR12110 board

and ensure the RED polarity

marks are facing the same

direction when

connecting the flight battery

to the AR12110 board

The system will

not connect

Your transmitter and

receiver are too close

together. They should be

8 to 12 feet apart

Move transmitter 8 to 12 feet

from receiver

You are around metal

objects

Move to an area with less

metal

Model selected is not the

model bound to

Check model selected and

ensure you are bound to

that model

Your transmitter was

accidentally put into bind

mode and is not bound to

your receiver anymore

Rebind your transmitter and

receiver

Receiver quits

responding during

operation

Inadequate battery voltage

Charge batteries. Spektrum

receivers require at least

3.5V to operate. An inad-

equate power supply can

allow voltage to momentarily

drop below 3.5V and cause

the receiver to brown out and

reconnect

Loose or damaged wires

or connectors between

battery and receiver

Check the wires and con-

nection between battery and

receiver. Repair or replace

wires and/or connectors

Receiver loses

its bind

Transmitter stand or tray

could be depressing the

bind button

If stand is depressing bind

button, remove from stand

and rebind

Bind button pressed be-

fore transmitter turned on

Rebind your system follow-

ing binding instructions

Receiver blinking

at landing

System turned on and

connected then receiver

turned off without turning

off transmitter

Turn off transmitter when

receiver is turned off

Advertising