Status display: device, Status display: fieldbus interface, Status display: drive−based safety – Lenze ELCAFHIxxx4E34NNPM Highline Benutzerhandbuch
Seite 47

l
47
EDKLCFH1134−EPM DE/EN 1.0
Status display: device
Pos.
Colour
State
Description
ERR
Red
Off
No fault
Blinking
Active fault
RUN
Green
On
Device enabled
Blinking
Device inhibited
IN1
Green
On
DI1 = HIGH
Off
DI1 = LOW
IN2
Green
On
DI2 = HIGH
Off
DI2 = LOW
...
...
...
...
IN7
Green
On
DI7 = HIGH
Off
DI7 = LOW
IN8
Green
On
DI8 = HIGH
Off
DI8 = LOW
OUT1
Yellow
On
DO1 = HIGH
Off
DO1 = LOW
OUT2
Yellow
On
DO2 = HIGH
Off
DO2 = LOW
OUT3
Yellow
On
DO3 = HIGH
Off
DO3 = LOW
OUT4
Yellow
On
DO4 = HIGH
Off
DO4 = LOW
Status display: fieldbus interface
Pos.
Colour
State
Description
BUS error
Red
Not active
BUS status
Green
Off
No communication with the PROFIBUS master
On
The communication with the PROFIBUS master is established.
Status display: drive−based safety
Pos.
Colour
State
Description
SAFE status
Yellow
On
Safe torque off (STO) is not active
Off
Safe torque off (STO) is active
SAFE error
Red
On
System error:
After a serious internal error STO is activated.
Off
Error−free operation
SAFE IN1
Green
On
The channels A and B are in the ON state.
Off
At least one channel is in the OFF state
SAFE IN2
Green
On
The channels A and B are in the ON state.
Off
At least one channel is in the OFF state
SAFE IN3
Green
On
The channels A and B are in the ON state.
Off
At least one channel is in the OFF state
SAFE IN4
Green
On
The channels A and B are in the ON state.
Off
At least one channel is in the OFF state
SAFE OUT1
Yellow
On
The channels A and B are in the ON state.
Off
At least one channel is in the OFF state
SAFE OUT2
Yellow
Not active