Electrical installation, Safety engineering – Lenze ELCAFHIxxx4E34NNPM Highline Benutzerhandbuch
Seite 76

Electrical installation
Safety engineering
l
76
EDKLCFH1134−EPM DE/EN 1.0
Detailed features of the safe inputs and the safe output
Terminal
Specification
[Unit]
min.
typ.
max.
I1A, I1B
I2A, I2B
I3A, I3B
I4A, I4B
AIE, AIS
PLC input, IEC−61131−2, 24 V, type 1
Low signal input voltage
V
−3
0
5
Input current at low signal
mA
15
High signal input voltage
V
15
24
30
Input current at high signal
mA
2
15
Input capacitance
nF
3.5
Repetition rate of the test pulses
ms
50
AIE, AIS
Input delay (operating time)
S
0.3
10
CLA, CLB
PLC output, IEC−61131−2, 24 V DC, 50 mA
Low signal output voltage
V
0
0.8
High signal output voltage
V
17
24
29
Output current
mA
60
Cable capacity
nF
100
Cable resistance of a passive sensor
W
200
O1A, O1B
PLC output, IEC−61131−2, 24 V DC
Low signal output voltage
V
0
0.8
High signal output voltage
V
17
24
29
Output current
mA
500
Cable capacity
nF
100
Cable resistance
W
200