Rated data, Technical data, 2 rated data input data – Lenze ELCAFHIxxx4E34NNPM Highline Benutzerhandbuch
Seite 61

Technical data
Rated data
l
61
EDKLCFH1134−EPM DE/EN 1.0
2.2
Rated data
Input data
Basis of the data
Mains
Mains voltage U
LN
[V]
Voltage range U
LN
[V]
Frequency range
[Hz]
3/PE AC
400
320 − 0 % ... 440 + 0 %
45 ... 65
3/PE AC
500
400 − 0 % ... 550 + 0 %
45 ... 65
Cyclic mains switching
Type
ELCAFHI5524
Max. 5 switchings / 5 minutes
ELCAFHI7524
ELCAFHI1134
Voltage
Frequency
Current (T
a1
)
1)
Current (T
a2
)
2)
Number
of phases
Typ
[V]
[Hz]
[A]
[A]
ELCAFHI5524
400/500
50/60
16.8/14.7
10.5/9.2
3
ELCAFHI7524
400/500
50/60
21.5/18.9
13.4/11.8
3
ELCAFHI1134
3)
400/500
50/60
21.0/18.5
13.1/11.6
3
ELCAFHI1134
4)
400/500
50/60
23.2/20.3
17.4/15.3
3
1)
Ta1 = max. 40 °C ambient temperature during operation
2)
Ta2 = max. 55 °C ambient temperature during operation
3)
Operation with mains choke ELN3−0150H024_001
4)
Operation without mains choke
Observe derating of output current, see table "Output data"!
Supply voltage for control electronics of the controller
(safely separated power supply unit SELV/PELV)
Typ
Voltage range U
DC
[V DC]
Current consumption at + 24 V DC [A]
Min.
1)
Max.
2)
ELCAFHI5524
+ 24
(+19.2 − 0 % ... +28.8 + 0 %)
1.9
4.4
ELCAFHI7524
ELCAFHI1134
1)
No digital inputs and outputs connected
2)