Key for the overview – Lenze ELCAMWIxxx4SNNPSNN (LCU 121) Benutzerhandbuch
Seite 38

l
38
EDKLCMW3024−SPS DE/EN 7.0
Key for the overview
Operational controls and connections
Pos.
Function
Description
0
Service switch
Triple locking
FE
Functional earth
M6 threaded bolts
X10
Mains connection
Connector: Pins, Harting HAN−Modular
X11
Connection for 24 V supply
Connector: Pins, Harting HAN−Modular
X21
Motor connection 1
Connector: Socket, Harting HAN−Modular
X31
PROFIBUS input
Connector: Pins, 5−pin, M12, B−coded
X32
PROFIBUS output or bus termination
Connector: Socket, 5−pin, M12, B−coded
X41
Digital inputs I1, I2
Connector: Socket, 4−pin, M12
X42
Digital inputs I3, I4
Connector: Socket, 4−pin, M12
X45
Digital outputs Q1, Q2
Connector: Socket, 4−pin, M12
X60
Safe inputs, safe outputs
Connector: Socket, 26−pin, M27, N−coded
X70
Diagnostic interface
Connector: Plug connector, 4−pin
X72
1)
Manual operation
Connector: Socket, 8−pin, M12
1)
Designation in production lot with hardware version PB: X20
Display elements
Pos.
Function
1
Plain text display, 4 lines, (20
characters per line)
Status "Operating mode"
Status "Inhibit"
Status "Motor 1"
"Motor 1 apparent current"
"Error abbreviation"
"Error in plain text"