Electrical installation – Lenze ELCAMWIxxx4SNNPSNN (LCU 121) Benutzerhandbuch
Seite 64

Electrical installation
Control connections
l
64
EDKLCMW3024−SPS DE/EN 7.0
Digital outputs
)
Note!
If inductive loads are being connected, it is essential to use a spark suppressor
at the digital output.
X45 − digital outputs A1, A2
Pin
Signal
Description
Data
Connector: socket, 4−pole, M12
1
+24 V
Supply
2
Signal 1
a1
HIGH
U
DC
at X11
3
GND
Reference potential
LOW
0 ... +4 V
4
Signal 2
A2
Max. 500 mA
Diagnostic interface
X70 − Diagnostic interface
Pin
Signal
Description
Data
1 ... 4
Connection for handheld keypad or PC
interface
Connector: Plug connector, 4−pin
Connection only possible using a Lenze
system cable E82ZWLxxx
Only use PC interfaces featuring electrical
isolation:
LECOM−A (RS232) EMF2102IBCV004 or
LECOM A/B (RS232/RS485)
EMF2102IBCV001
Automatic / manual operation
)
Note!
Manual operation is only possible if the motor starter is enabled by the safety
PLC!
X72
1)
− Manual operation
Pin
Signal
Description
Data
Connector: Socket, 8−pin, M12
1
+24 V
Supply (switch in manual operation)
2
Signal 1
Input automatic/manual operation
HIGH
Manual operation
LOW
Automatic operation
3
GND
Reference potential
4
HI1
Input 1
HIGH
CW rotation
5
HI2
Input 2
HIGH
CCW rotation
6 ... 8
Reserved
1)
Designation in production lot with hardware version PB: X20