Status display: drive−based safety – Lenze ELCAMWIxxx4SNNPSNN (LCU 121) Benutzerhandbuch
Seite 40

l
40
EDKLCMW3024−SPS DE/EN 7.0
Status display: drive−based safety
lcu121_000h
Pos.
Colour
State
Description
MS
Green
on
Integrated safety technology has been properly initialised.
off
Integrated safety technology has not been initialised.
Confirmation is not possible.
EN
Yellow
On
Controller enabled
Off
Non−safe display "STO"
ME
Red
On
System error:
l
After a serious internal error STO is activated.
l
Reset is only possible by switching the 24−V supply.
Blinking
Error:
l
After an internal error or an error on the sae inputs or outputs, STO
is activated.
l
The safety class is exited.
l
Confirmation is possible.
Off
Error−free operation
PS
Red
On
Error PROFIsafe:
l
Communication is not possible.
l
Acknowledgement is possible.
Blinking
No valid PROFIsafe configuration
Off
PROFIsafe is error−free.
SI1
green
on
Channels A and B are ON
off
At least one channel is OFF
SI2
green
on
Channels A and B are ON
off
At least one channel is OFF
SI3
green
on
Channels A and B are ON
off
At least one channel is OFF
SI4
green
on
Channels A and B are ON
off
At least one channel is OFF
SO1
yellow
on
Channels A and B are ON
off
Channels A and B are OFF
SO2
yellow
on
Channels A and B are ON
off
Channels A and B are OFF