16

Reviewingthesetup
For review mode, press the

Å

and

ì

keys simultaneously.

Press the

Å

and

ì

keys to move through the setup sequence (see

table). Greyed items in the setup table are not shown in review mode.
A 10 s timeout applies for review mode or you can press to quit.
Note: You can use review mode while the instrument is in service and
the analogue output and alarms will continue to operate correctly.

Changingthesetup
For setup mode, connect the security link and press the

Å

and

ì

keys simultaneously. The software version will be displayed (flashing). If
you wish to continue, press within 10s.
During setup the

Å

and

ì

keys change values and toggle options.

The key accepts changes and moves to the next item in the setup
sequence (see table).
Note: If you remove the security link before the end of the setup
sequence, any changes you have made will not be saved.

Clearingtrippedalarms
You can acknowledge a tripped alarm by simply pressing the key for
that channel ( ï for Alarm 1 or ENT for Alarm 2).

Displayingthealarmsetpoints
To check a setpoint, simply press the key for that channel ( ï for Alarm
1 or ENT for Alarm 2). If the alarms are disabled the display will show
---- .