8 montage und ausrichtung des sensors, Montage und ausrichtung des sensors, Assembly and adjustment of the sensor – Baumer ITDx9 Benutzerhandbuch

Seite 15: 8assembly and adjust- ment of the sensor, 8montage und ausrich- tung des sensors

Advertising
background image

8

Assembly and adjust-

ment of the sensor

8.1.1

Distance band set between the sen-

sor and rotor for the positioning, af-

ter this put the sensor on the rotor.

During the assembly and adjustment

must not reach any foreign particle

between sensor, distance band and

rotor.

8.1.2

The sensor fasten to the motor hou-

sing. Both long holes in the sensor

are planned for thread screws M3.

8.1.3

At the adjustment of the sensor is to

be paid attention to the fact that the

distance band lies smooth between

rotor and sensor.

8.1.4

After end of the mounting remove

the distance band.

8

Montage und Ausrich-

tung des Sensors

8.1.1

Distanzband zwischen Sensor und

Rotor zur Positionierung legen, da-

nach Sensor an Rotor anlegen.

Während der Montage und Aus-

richtung dürfen keine Fremdpartikel

zwischen Sensor, Distanzband und

Rotor gelangen!

8.1.2

Den Sensor am Motorgehäuse be-

festigen. Die beiden Langlöcher am

Sensor sind für Gewindeschrauben

M3 vorgesehen.

8.1.3

Bei der Justierung des Sensors ist

darauf zu achten, dass das Distanz-

band leichtgängig zwischen Rotor

und Sensor liegt.

8.1.4

Nach Abschluss der Montage das

Distanzband entfernen.

motor housing

distance band

washer

(customer supplied)

rotor

sensor

fastening screw

(customer supplied)

Motorgehäuse

Distanzband

U-Scheibe

(kundenseitig)

Rotor

Sensor

Befestigungs-

schraube

(kundenseitig)

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

5

6

Anschlussbelegung, Terminal assignment

Baumer_ITDx9_II_DE-EN_1309.indd

15