9. Programming plan
Zl 11-16
Status for Line 1-6
0 * Parameter can be changed
1
Clearing and/or input disabled
2
Parameter is skipped
Line 23
Input logic for control inputs
0 * Operating threshold 6 V
1
Operating threshold 3 V
Line 24
Decimal point for tachometer F
0 * No decimal point
1
00000.0
2
0000.00
3
000.000
Line 26
Offset
0 * No offset
1
Offset 2V/4mA without monitoring < 2V
2
Offset 2V/4mA with monitoring < 2V
Line 28
Update time (repeated display)
0
0,1 s
1
0,5 s
2 * 1 s
3
2 s
4
3 s
5
5 s
6
10 s
7
20 s
8
30 s
9
60 s
Line 31
Function of control input 1
0 * Hold
1
Reset maximum-value memory
2
Programming disable
3
Keylock
4
Line 32
Function of control input 2
0
Hold
1 * Reset maximum-value memory
2
Programming disable
3
Keylock
4
Line 33
Allotment output P1
0 * Top limit value tachometer
1
Bottom limit value tachometer
Line 34
Allotment output P2
0 * Top limit value tachometer
1
Bottom limit value tachometer
Line 35
Output logic for relay outputs
0 * Both outputs as normally open
1
Out 1 normally closed, Out 2 normally open
2
Out 1 normally open, Out 2 normally closed
3
Both outputs as normally closed
Line 39
Hold delay time
0 * No delay
1
Delay 1 s
:
4
Delay 9 s
Line 40
Code setting
0000 * Code not active
:
9999
Line 51
Baud rate
0 * 4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Line 52
Parity
0 * Even
1
Odd
2
No
Line 53
Stop bits
0 * 1 stop bit
1
2 stop bits
Line 54
Device address
00 * Minimum value
:
99
Maximum value
Line 55
Allotment output value via interface
0 * F
1
SZ
Line 56
RS422: Control connections TxD+,TxD-
0 * switched in sense of transmission for
transmission, in sense of reception for
reception
1
Always in sense of transmission