Operating plan, Pc - main counter 2, P1 - preset value 1 3 – Baumer NE134 Benutzerhandbuch
Seite 13: P2 - preset value 2 4, Sc - start count 5, Tot - totalizer 6, B - batch counter 7, Sf - scaling factor, Separating line, Pc - main counter 12

NE134
www.baumer.com
13
8. Operating Plan
Line Default
Customer
Settings Short
Description
1
0
1 P C
PC - Main counter
2
1 0 0
2 P 1
P1 - Preset value 1
3
1 0 0 0
3 P 2
P2 - Preset value 2
4
0
4 S C
SC - Start count
5
0
5 t o t
tot - Totalizer
6
0
6 b
b - Batch counter
7
1.0 0 0 0
7 S F
SF - Scaling factor
10
- - - - - -
Separating line
11
S t A t 0
1 1 P C
PC - Main counter
12
S t A t 0
1 2 P 1
P1 - Preset value 1
13
S t A t 0
1 3 P 2
P2 - Preset value 2
14
S t A t 2
1 4 S C
SC - Start count
15
S t A t 2
1 5 t o t
tot - Totalizer
16
S t A t 2
1 6 b
b - Batch counter
17
S t A t 2
1 7 S F
SF - Scaling factor
20
- - - - - -
Separating line
21
0
2 1
Operating modes main counter
22
0
2 2
Preset
mode
23
0
2 3
Kind of reset
24
0
2 4
Decimal point for PC, (P1,) P2, SC and tot
26
0
2 6
Measuring unit displayed
27
2
2 7
Lower display assignment
30
0
3 0
Counting
mode
31
0
3 1
Frequency main counter track A
32
0
3 2
Frequency main counter track B
33
0
3 3
Input logic and signal input switching
threshold
34
0
3 4
Function Control input 1 (Assignment 9)
35
0
3 5
Minimum impulse duration of Control input 1
36
2
3 6
Function Control input 2 (Assignment 10)
37
0
3 7
Function Control input 3 (Assignment 11)
38
0
3 8
Adoption of presets P1, P2, SC
40
0
4 0
Output
logic