Programming plan, Output time p1 42, Output time p2 – Baumer NE134 Benutzerhandbuch
Seite 14: Code setting 51, Baudrate 52, Parity 53, Stop bits 54, Address, Separating line, Ne134

NE134
14 www.baumer.com
41
0.2 5
4 1
Output time P1
42
0.2 5
4 2
Output time P2
50
0 0 0 0
5 0
Code
setting
51
0
5 1
Baudrate
52
0
5 2
Parity
53
0
5 3
Stop
bits
54
0 0
5 4
Address
55
- - - - - -
Separating line
9. Programming Plan
Lines 11-17 Status of lines 1-7
0
Parameter alteration accessed
1
Clear resp. input lock
2
Skip parameter
Line 21
Operation Modes Main counter
0 *
Add. – Reset to SC, Stop contact P2
1
Sub. - Autoreset at SC, Stop contact at SC
2
Sub. - Autoreset at 0, Stop contact at SC
Line 22
Preset Mode
0 *
Main counter 2 presets (step presets)
1
Main counter 2 Presets (P1 = trailing
preset)
2
Main counter with preset P2, batch with P1
Line 23
Kinds of Reset
0 *
Main counter and batch counter with
autoreset
1
Main counter w/o,batch counter with
autoreset
2
Main counter with,batch counter w/o
autoreset
3
Main counter and batch counter w/o autoreset
Line 24
Decimal Point for PC, (P1,) P2, SC and tot
0 *
No decimal point
1
00000.0
2
0000.00
3
000.000
Line 26
Measuring unit displayed
0 *
No measuring unit
1
m
2
dm
3
cm
4
mm
5
L
Line 27
Lower Dispaly Assignment
0
W/o lower display
1
P1 - Preset value
2 *
P2 - Preset value
3
SC - start count
4
tot – totalizer
5
b - batch counter
6
SF - scaling factor
Line 30
Counting Mode
0 *
Count track A / direction inversion track B
1
Difference (A-B)
2
Total (A+B)
3
Track A 90° B single evaluation
4
Track A 90° B double evaluation
5
Track A 90° B fourfold evaluation
Line 31
Frequency Main counter track A
0 *
10 kHz
1
25 Hz
2
3 Hz
Line 32
Frequency Main counter track B
0 *
10 kHz
1
25 Hz
2
3 Hz