Ne134 – Baumer NE134 Benutzerhandbuch
Seite 15

NE134
www.baumer.com
15
Line 33
Input logic and switching threshold
0 *
PNP Switching threshold 6V
1
NPN Switching threshold 6V
2
PNP Switching threshold 3V
3
NPN Switching threshold 3V
Line 34
Control input 1 function (assignemnt 9)
0 *
PC Main counter - static reset
1
PC Main counter - edge active reset
2
PC Main counter and totalizer - Stop
3
Hold
4
Programming lock
5
Key lock
6
Print (min. impulse width 30ms)
7
Outputs P2 (P1) ON (PR_MODE inverted)
8
Outputs P2 (P1) OFF
Line 35
Min. Impulse width of control input 1
0 *
30 ms
1
100 µs
Line 36
Function control input 2 (assignment 10)
0
PC Main counter – static reset
1
PC Main counter - edge active reset
2 *
PC Main counter and totalizer - Stop
3
Hold
4
Programming lock
5
Key lock
6
7
Outputs P2 (P1) ON (PR_MODE inverted)
8
Outputs P2 (P1) OFF
9
ext. count input of batch counter
Line 37
Function control input 3 (assignment 11)
0 *
tot totalizer – static reset
1
tot totalizer - edge active reset
2
b Batch counter – static reset
3
b Batch counter - edge active reset
4
Programming lock
5
Key lock
6
7
Outputs P2 (P1) ON (PR_MODE inverted)
8
Outputs P2 (P1) OFF
9
external Count input of Batch counter
Line 38
Adoption of presets P1, P2, SC
0 *
Immediately effective
1
Effective after reset
Line 40
Output logic
0 *
Both outputs as normally closed
1
P1 as normally open, P2 as normally closed
2
P1 as normally closed, P2 as normally open
3
Both outputs as normally open
Line 41
Output time P1
0.01
Minimum signal duration
0.25 * Default
99.99
Maximum signal duration
Latch
Latch (by pressing the C key)
Line 42
Output time P2
0.01
Minimum signal duration
0.25 * Default
99.99
Maximum signal duration
Latch
latch (by pressing the C key)
Line 50
Code settings
0000 * Code not active
:
9999
Line 51
Baudrate
0 *
4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Line 52
Parity
0 *
Even Parity
1
Odd Parity
2
No Parity
Line 53
Stop bits
0 *
1 Stop bit
1
2 Stop bits
Line 54
Address
00 *
Default
00
Min.
99
Max.