4 technical data - electrical ratings (sinewave), 5 technical data - mechanical design, Technical data - electrical ratings (sinewave) – Baumer MHAP 200 Benutzerhandbuch

Seite 27: Technical data - mechanical design

Advertising
background image

MB221T1 - 11105054

Baumer_MHAP200-T1_II_DE-EN (14A4)

24

8

8.4

Technical data - electrical ratings (sinewave)

• Voltage supply (Signals):

P...D:

4,5...30 VDC (SinCos)

• Consumption w/o load:

≤300 mA

• Sinewave cycles per turn:

1...16384 (As ordered)

• Phase shift:

90° ±5°

• Sensing method:

Magnetic

• Output signals:

A+, A-, B+, B-

• Output stage:

SinCos 1 Vpp

• Difference of SinCos amplitude:

≤20 mV

• Harmonics typ.:

-40 dB

• DC offset:

≤20 mV

• Bandwidth:

400 kHz (-3 dB)

8.5

Technical data - mechanical design

• Sensor head:

FPGA signal processing

• Size (flange):

ø203.1 mm

• Shaft type:

ø50...180 mm (through hollow shaft)

(As

ordered)

• Axial tolerance:

±1 mm (wheel/head)

• Radial tolerance:

0.1...0.5 mm (wheel/head)

• Protection DIN EN 60529:

IP 67 (head)

IP

68

(wheel)

• Operating temperature:

-20...+85 °C

• Operating speed:

≤4000 rpm

• Resistance:

IEC

60068-2-6:2007

Vibration 30 g, 55-2000 Hz

IEC

60068-2-27:2008

Shock 300 g, 2 ms

• Accuracy of magnetic measure:

±200 ″

• Connection:

Flange connector M23, 17-pin

Advertising