5 teaching the oadr – Baumer BA OADR20 Benutzerhandbuch

Seite 31

Advertising
background image

120717_Manual_OADR20i6xx_DE_EN_V5.DOC

31/40

Baumer

18.07.12

Frauenfeld, Switzerland

5 Teaching the OADR

Every sensor is delivered with the factory setup (max. measuring range). The teach-in feature was designed
to choose a smaller range within the nominal measuring range for optimizing the resolution and linearity.
Output current, output voltage and alarm output adapt to the new range. Two positions must be taught.

•

The first teach-in position aligns with 0 V (or 4 mA) the second position aligns with 10 V (or 20 mA)

•

These teach-in positions are always just at the limit of the new range (inside the measuring range)

•

The sensor may be taught more than 10’000 times in its lifetime

•

The sensor can always be reset to its factory settings

•

The sensor may be taught using the external teach input

•

During the teach-in process the red LED provides visual feedback to the operator

•

When in running mode the red LED on the back side of the sensor indicates whether there is an object

within the measuring range or not.


Example of a taught measuring range:



Example of a reverse taught measuring range:


30 mm

130 mm

0V / 4mA

Analog out

10V / 20 mA

Example
of a
taught
output
curve

LED

Standard output

curve

30 mm

130 mm

0V / 4mA

Analog out

10V / 20mA

Example of
a reversed
output
curve

LED

Standard output

curve