Technical data – Baumer BA OADR20 Benutzerhandbuch

Seite 36

Advertising
background image

120717_Manual_OADR20i6xx_DE_EN_V5.DOC

36/40

Baumer

18.07.12

Frauenfeld, Switzerland

Technical data

OADR 20I6465/S14F

OADR 20I6565/S14F

OADR 20I6475/S14F

OADR 20I6575/S14F

OADR 20I6485/S14F

OADR 20I6585/S14F

Function

Measuring sensor

Technology

Laser Triangulation

Measuring ranges MB

30...130mm

50.....300mm

100...600mm

Resolution typical

0.005...0.06mm

0.01...0.33mm

0.015...0.67mm

Linear deviation (white ceramics)

< ±0.015... ±0.20mm

< ±0.03... ±1.0mm

< ±0.05... ±2.0mm

Light source

Laser diode red, pulsed

Wavelength

Red light 650nm

Laser beam diameter (64xx)

2...1mm

2mm

2mm

Laser beam width (65xx)

3...5mm

4...12mm

5.5...21mm

Laser beam height (65xx)

2...1mm

2.5mm

2.5mm

Color sensitivity typ.

< 2 x the actual resolution

Suppression of mutual

interference

No active suppression

The synchronization input may be used for asynchronous operation

Temperature drift typical

< ±0.03% of MB / °C

< ±0.0 3% of MB / °C

< ±0.03% of MB / °C

Ambient light immunity

< 40 kLux

< 8 kLux

< 10 kLux

Measuring rate (depending on

object reflectivity)

300....900us

300....900us

300....2800us

Response time

< 2 x measuring rate

Release time

< 4 x measuring rate

Power on indicator

yes, LED green

Alarm

yes, LED red

Voltage supply range +Vs

12 … 28 VDC

Current consumption

< 100 mA, (at +24V ~40mA)

Analog output

4...20mA and 0...10V

Load resistor at I-Out

< (+Vs - 6V) / 0.02A

Load resistor at U-Out

>100k @ +Vs = 12V .

>10k @ +Vs = 15...28V

Alarm output

yes (high signal beyond MB)

Alarm output type

PNP

Alarm output load current

100 mA

Voltage drop at PNP

alarm output

max: < +Vs -(4.0V) @ 100mA

typ: +Vs -(2.4V) @ 100mA

Short circuit protection (analog I-

Out, analog U-Out, Alarm-Out)

yes

Reverse polarity protection

yes (supply only)

Material of housing

Stainless steel 1.4404

Material of front optics

PMMA

Material of light guide

PMMA

*

1)

and

*

2)

measured on white ceramic sheet

*

3)

the response time depends on the reflectivity of the object

For objects with a reflectivity < 7% (OADM 20x2480/S14C), the response / release time is increased automatically

up to max. 2.8 ms.

*4)

Missed measurements up to 30 cycles will be suppressed. During this time the analog output stays on hold.

*5)

xx% of full scale measuring range / °C

*

6)

maximum sunlight on a white measuring surface