Salter Brecknell LP-250 Series Benutzerhandbuch

Seite 34

Advertising
background image

 

 

 

Power on utilities

The LED color will be changed as following pattern:

4. Set black mark sensor as media

sensor and calibrate the black mark

sensor

Release

4.3.1 Gap/Black Mark Sensor Calibration

Gap/black mark sensor sensitivity should be calibrated at the following conditions:

1. A brand new printer

2. Change label stock.

3. Printer initialization.

Please follow the steps below to calibrate the gap/black mark sensor.

1. Turn off the power switch.

2. Hold on the button then turn on the power switch.

3 Release the button when LED becomes red and blinking. (Any red will do during the 5

blinks).

It will calibrate the gap/black mark sensor sensitivity.
The LED color will be changed as following order

Amber

red (5

amber (5 blinks)

solid green

green (5 blinks)

green/amber (5 blinks)

red/amber (5 blinks)

Note:

1. Sensor calibration can be done by Diagnostic Tool or by power on utility. Please refer to

“

3.3

Diagnostic Tool

”

Section for more information.

2. Please select gap or black mark sensor type prior to calibrate the sensor.

4.3.2 Gap/Black Mark Calibration, Self-test and Dump Mode

28

Amber

Solid green

Release

Release

LED color

Functions

Red

(5 blinks)

Amber

(5 blinks)

Green

(5 blinks)

Green/Amber

(5 blinks)

Red/Amber

(5 blinks)

1. Gap / black mark sensor calibration

Release

2. Gap / black mark sensor calibration,

Self-test and enter dump mode

3. Printer initialization

Release








5. Set gap sensor as media sensor and

calibrate the gap sensor

6. Skip AUTO.BAS

Release