Technische daten – EXFO AXS-200/610 Copper Test Module Benutzerhandbuch

Seite 190

Advertising
background image

Technische Daten

180

AXS-200/610

PSD NOISE MEASUREMENT

Test type

Continuous or peak-hold

Vertical scale

–10 dBm/Hz to –145 dBm/Hz or +20 dBm to –110 dBm

Horizontal scale

4.3125 kHz to 17 MHz, in 4.3125 kHz steps or 8.625 kHz to 30 MHz, in 8.625 kHz steps

Noise filters

None or E, F, G, VDSL2-8, VDSL2-12, VDSL2-17 and VDSL2-30

DSL IMPULSE NOISE MEASUREMENT

Threshold

–50 dBm (40 dBrn) to 0 dBm (90 dBrn) in 1 dB steps

Counter

Maximum 65 000

Test duration

1, 5, 10, 15 and 60 min, 24 h or continuous (up to 360 h)

Histogram plot interval

1, 5, 10, 15 or 60 min

Uncertainty (accuracy) (dB)

±2

SWEPT LONGITUDINAL BALANCE TEST

Frequency accuracy (ppm)

±50

Uncertainty (accuracy)(dB)

±2.0

Vertical scale (dB)

0 to 80.0 up to 2.2 MHz
0 to 60.0 up to 30 MHz

Horizontal scale

ADSL/2+: 26 kHz to 2.2 MHz
SHDSL: 26 kHz to 1 MHz
VDSL/VDSL2-12: 26 kHz to 12 MHz
VDSL2-17: 26 kHz to 17.66 MHz
VDSL2-30: 26 kHz to 30 MHz

DMM (DIGITAL MULTIMETER)

Measurement

Range

Resolution

Accuracy

DC voltage

0 to 200 V

1 V

the better of ±2 % or ±1 V

AC voltage

0 to 140 Vrms

1 V

the better of ±2 % or ±1 V

Resistance

0 to 999 M

Ω

3 digits

0 to 999

Ω

the better of ±2 % or ±5

Ω

1 k

Ω to 99 MΩ

the better of ±2 % or ±1 digit

100 M

Ω to 999 MΩ

the better of ±5 % or ±1 digit

Distance up to 30 000 m (100 000 ft)

Capacitance

1 nF to 10

µ F

3 digits

the better of ±2 % or ±1 digit

Distance up to 30 000 m (100 000 ft)

DC current

0 to 110 mA

1 mA

the better of ±2 % or ±1 digit

AC current

0 to 77 mA

1 mA

the better of ±2 % or ±1 digit

SPECTRAL DETECTIVE

Allows the AXS-200/625 to bridge (high-impedance) onto a live circuit to display a plot of transmitted levels and spectrum (PSD). The Spectral Detective test can be
referenced to any user-selected impedance. The impedance reference setting is required to display proper readings in dBm/Hz or dBm.
Test type

Continuous or peak-hold

Bridging impedance (k

Ω)

15 k

Ω

Vertical scale

–10 to –145 dBm/Hz or +20 to –110 dBm

Horizontal scale

4.3125 kHz to 17 MHz, in 4.3125 kHz steps or 8.625 kHz to 30 MHz, in 8.625 kHz steps

Noise filters

None or E, F, G, VDSL2-8, VDSL2-12, VDSL2-17 and VDSL2-30

STRESS/LEAKAGE (ISOLATION RESISTANCE)

Source

100 VDC, current safely limited to < 1.0 mA

Range (M

Ω)

0 to 999 auto-ranging

Resolution

3 significant digits

Uncertainty (accuracy)

0 to 999

Ω , the better of ±1 % or ±5 Ω

1 k

Ω to 99 MΩ , the better of ±1 % or ±1 digit

100 M

Ω to 999 MΩ , the better of ±5 % or ±1 digit

Soak timer (s)

1 to 99

RFL

Test type

Single pair and separate good pair

Fault detection (M

Ω)

0 to 20

Resolution

3 digits

Loop resistance (k

Ω )

7 maximum

Multiple cable sections

Five (includes gauge and temperature setting)

Fault location

*Total resistance, near-end to fault resistance, fault to strap resistance (four significant digits)
*Total length, distance to fault, distance from fault to strap (3 ft/1 m resolution)

Uncertainty (accuracy) (

Ω )

The better of 0.2

Ω or ±2 %

Advertising