2. Installation

2.1 Powering the fixture

Install a 3-prong gounding type plug that fits your supply
Connected load: voltage 230V, frequency 50Hz, Power 340 VA

WARNING: To ensure propper installation of the plug consult a qualified

technician!

2.2 Installing or changing the lamp

WARNING: Disconnect fixture from mains, and allow hot lamp to cool down

for at least 30 minutes!

fan

1

Sketch: backside view of head

lamp type: OSRAM HTI 150W

Remove both screws
no.1 (see drawing)

Remove lamp holder gently from the case
by pulling it backwards.

If changing the lamp, remove old lamp from
lamp socket. Hold the new lamp only by its
ceramic base. Never touch the glass bulb.
Insert the new lamp in the lamp socket.

Re-insert the lamp holder and tighten the
scews. Make sure the cables do not get
damaged during the process.

lamp holder

2.3 Rigging the fixture

The Varyscan MICRO 150HTI can either be placed on the floor or hung on a
trussing system.
If mounting the unit to walls in a vertical way, the lamplife might be reduced.

WARNING: Keep fixtures at least 1 m away from inflamable articles!

Always use a safety cable attached to the base!

brown

live

“L”

blue

neutral

“N”

yellow/green gound

Advertising