2 Mounting instructions

2.1 Delivery

The PHÖNIX type 740.0060/65 level switch can be delivered in the configurations shown below:

Fig. 3a: as delivered

Fig. 3b: with inverted switching di-

rection

2.2 Reversing the direction of switching

A reversal of the direction of switching involves the opposite switching function. Please note that the ca-
ble-gland is always directed downwards, as shown in fig. 3a and 3b.

Instruction:

• Remove the switch cover

• Remove the safety access panel (type 740.0060 only)

• If necessary remove all connecting wires from the terminal

• Take off screw, hexagon bolt and - for aluminium housing - the earth terminal

• After turning the circuit board 180° remount with screws , hexagon bolt and.- for aluminium housing-

the earth terminal.

• Reconnect the wires into the terminal

• Put on the safety access panel (type 740.0060 only, very important !!)

OFF

OFF

ON

ON