7 Disposal
The customer/enduser is obliged to take care for the disposal within the legal regulations.
8 Trouble shooting
Failure Problems Correction
no function
wrong wiring, fuses, current supply
check it
no bistable behaviour
wrong mounting of the housing
rise distance
the switch is always closed
(740.0060)
power switch: low current
Mini-switch: supply voltage > 24V
use it as a mini-switch
remove resistor R1
the switch opens spontane-
ously (miniswitch)
load is too high
temperature is too high
use an isolating switch amplifier
use a heat protection plate
9 Technical Data
General Data
Design Data
Hysteresis ca. [mm]
Cable gland downwards
IP65
Alu/Makrolon
with strap retainers
(Accesories s. page 2)
Makr.: 82x80x55/0,15 kg
Alu: 75x80x57/0,3 kg
Gauge-Type
on basic pipe
on heating jacket
710.104/2XX
710.100
710.110...160
6
10
15
15
20
25
Operating mode
M
a
k
r.
A
lu
M
a
k
r.
A
lu
max. temperature
of pipe
max. temp.
of housing
150 °C *)
at amb.Temp.85 °C
70 °C
Power switch
(Solid state
Triac-relay)
Small signal
switch
(Reed)
400 °C *)
at amb.Temp.55 °C
90 °C
150 °C *)
at amb.Temp.120 °C
500 °C *)
at amb.Temp.70 °C
120 °C
120 °C
*)Insulate between housing and pipe above
150 °C in pipe
Electrical data power switch
Electrical data miniswitch
Operating voltage nominal:
Operating voltage limit:
Load current nominal:
OFF-current (230 V~)
max. power limit:
24 V~ to 230V~
250 V~
24 mA~ to 2,5 A~
6 mA~
550 VA
Operating voltage limit:
Operating current limit:
Rupturing capacity UxI
max
:
400 V= / 230 V~
0,5 mA
5 W
-
1)
Take into account that none of the three parameters U
max
, I
max
, P
max
may be exceeded!
(