Siemens Industrial Ethernet Scalance X005 Benutzerhandbuch

Seite 46

Advertising
background image

Product Characteristics

4.4 SCALANCE X005 TP Ports

port of a partner device allowing automatic configuration of different types of device. With

autonegotiation, two components connected to a link segment can exchange parameters

and set themselves to match the supported communication functionality.

Note
Devices not supporting autonegotiation must be set to 100 Mbps/ half duplex or 10 Mbps half

duplex.

Auto polarity exchange

If the receive line pair is incorrectly connected (RD+ and RD- switched), the polarity is

automatically adapted.

Note
The SCALANCE X005 is a plug and play device which does not require settings for

commissioning.

MDI /MDIX Autocrossover Function

The advantage of the MDI /MDIX autocrossover function is that straight-through cables can

be used throughout and crossover Ethernet cables are unnecessary. This prevents

malfunctions resulting from mismatching send and receive wires. This makes installation

much easier for the user.
The SCALANCE X005 device supports the MDI / MDIX autocrossover function.

Notice
Fixed configured ports of partner stations must be set to 100 Mbps/ half duplex or 10 Mbps

half duplex.

Notice
Please note that a direct connection of two ports or an unintentional connection via several

switches causes an unpermissible loop which may cause network overload and network

failures.

Industrial Ethernet SCALANCE X005

4-4

Commissioning Manual, A2B00051528A

Advertising