4.5 SCALANCE X005 Power Supply

4.5 SCALANCE X005 Power Supply

Power Supply

The power supply is connected using a 2-pin plug-in terminal block. The power supply is

connected over a high resistance with the enclosure to allow an ungrounded setup. The

power supply is non-floating.

Figure 4-3

Power supply

Figure 4-4

Connector pinout

Pin number Pinout
Pin 1

M (Mass)

Pin 2

L+ (+18 - 32V DC)

Warning
The SCALANCE X005 device is designed for operation with safety extra-low voltage. This

means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/

VDE0805 can be connected to the power supply terminals.
The power supply unit to supply SCALANCE X005 must comply with NEC Class 2 (voltage

range 18 - 32 V, current requirement 350 mA).
Never connect SCALANCE X005 to AC voltage.

Never connect SCALANCE X005 to DC voltage higher than 32 V DC.

4.6 SCALANCE X005 LEDs

Power indicator (green LED)

The status of the power supply is indicated by a green LED:

Status

Meaning

Lit green

Power supply is connected.

Not lit

Power supply is not connected or <14 V

Industrial Ethernet SCALANCE X005
Commissioning Manual, A2B00051528A

4-5