Installation and Maintenance

5.5 Grounding

5.5 Grounding

Installation on a DIN Rail

The device is grounded over the DIN rail.

S7 Standard Rail

The device is grounded over its rear panel and the neck collar screw.

Wall Mounting

The device is grounded by the securing screw in the unpainted hole.
Please note that SCALANCE X005 must be grounded over one securing screw with

minimum resistance.
If the device is mounted on a non-conducting surface, it is required to install a grounding

cable. The grounding cable is not included in the delivery. Connect the unpainted surface of

the device to the next grounding point via the grounding cable.

Industrial Ethernet SCALANCE X005
Commissioning Manual, A2B00051528A

5-5