4.7 SCALANCE X005 Technical Specifications

Permitted Environmental Conditions / EMC
Operating temperature

0°C to +65°C

Storage/transport temperature

-40°C to +80°C

Relative humidity in operation

‹ 95% (no condensation)

Operating altitude

2000 m at max 46 °C ambient temperature

3000 m at max. 40 °C ambient temperature

RF interference level

EN 61000-6-2 Class A

(replaces EN 50081-2 Class A)
EN 61000-6-2 Class B with split toroidal core on

the lines

Manufacturer: Würth Elektronik - type:

742 711 31

Noise immunity

EN 61000-6-4

(replaces EN 50082-2)

Degree of protection

IP 30

Approvals

UL 60950

c-UL-us

Corresponds to CSA C22.2 No. 60950

C-TICK

AS/NZS 2064 (Class A).

CE

EN 61000-6-2, EN 61000-6-4

(replaces EN 50081-2)

MTBF
MTBF

167.1 years

Construction
Dimensions (W x H x D) in mm

40 x 125 x 124

Weight in g

550

Installation options

DIN rail
S7-300 standard rail
Wall mounting

Order Numbers
SCALANCE X005

6GK5005-0BA00-1AA3

Industrial Ethernet TP and Fiber Optic

Networks” manual

6GK1970-1BA10-0AA0

IE FC stripping tool

6GK1901-1GA00

IE FC blade cassettes

6GK1901-1GB00

IE FC TP standard cable GP

6XV1840 2AH10

IE FC TP trailing cable

6XV1840-3AH10

IE FC TP marine cable

6XV1840-4AH10

IE FC TP trailing cable GP

6XV1870-2D

IE FC TP flexible cable GP

6XV1870-2B

IE FC RJ-45 plug 180 pack of 1

6GK1 901-1BB10-2AA0

IE FC RJ-45 plug 180 pack of 10

6GK1 901-1BB10-2AB0

IE FC RJ-45 plug 180 pack of 50

6GK1 901-1BB10-2AE0

Industrial Ethernet SCALANCE X005
Commissioning Manual, A2B00051528A

4-7

Advertising