WIKA operating instructions models TR31-3, TR31-K

Thermometer with direct sensor output with Pt100

(model TR31-x-x-Px) and Pt1000 (model TR31-x-x-Sx)

Temperature range

without neck tube -50 ... +150 °C

(-58 ... +302 °F), with neck tube

-50 ... +250 °C (-58 ... +482 °F)

7)

Temperature at the connector or

at the directly connected cable

max. 85 °C (185 °F)

Measuring element

Pt100

(measuring current: 0.1 ... 1.0 mA)

Pt1000

(measuring current: 0.1 ... 0.3 mA)

Connection method

2-wire

3-wire

4-wire

Tolerance value of the measuring

element per IEC 60751

Class A

8)

Class B at 2-wire

Electrical connection

M12 x 1, 4-pin circular connector

Directly connected cable

7)

Version with mineral-insulated sheathed cable can be used up to 300 °C (572 °F).

8) Class accuracy A only valid in the temperature range -30 ... +150 °C (-22 ... +302 °F) or

-30 ...+250 °C (-22 ... +482 °F), otherwise class B

For detailed specifications for Pt sensors, see Technical information IN 00.17 at

www.wika.com.

Case

Material

Stainless steel

Ingress protection

Case with connected connector

9)

or directly connected cable

Coupler connector, not connected

IP 67 and IP 69K per IEC 60529/

EN 60529

IP 67 per IEC 60529/EN 60529

Weight in kg

ca. 0.2 ... 0.7

(depending on version)

Dimensions

see “Dimensions in mm”

9) The stated ingress protection only applies when plugged in using mating connectors that have

the appropriate ingress protection.