Enerpac PR-Series Electric Benutzerhandbuch

Seite 12

Advertising
background image

12

Table 10 - Troubleshooting Guide (Continued)

Symptom

Possible Cause

Solution

6. Cylinder extends but

will not retract.

Internal pressure leaks, or leaking retract

hoses.

Have hydraulic system inspected by Enerpac authorized service center.

Repair or replace components as required.

Internal relief valve setting or retract side

relief valve setting too low.

Have hydraulic system inspected by Enerpac authorized service center.

Repair or replace components as required.

Defective over-center valve, secondary

lock valve or control valve.

Have hydraulic system inspected by Enerpac authorized service center.

Repair or replace components as required.

Pump not developing enough pressure.

Have hydraulic system inspected by Enerpac authorized service center.

Repair or replace components as required.

7. Pump does not run.

No power or incorrect power.

Check AC line power.

Jack circuit breaker tripped.

(single-phase models only)

Depress circuit breaker reset button (on jack electrical enclosure).

Jack motor overload relay tripped.

(three-phase models only)

Depress reset button on motor overload relay (inside jack electrical

enclosure).

Transformer primary or secondary fuse

blown.

Remove both fuses and check them for continuity.

If one or both fuses are blown, check line voltage to be sure it is correct

for your jack model. Verify that the fuses installed are of the correct type

and rating. Refer to Table 9.

Note: A damaged pendant cable can cause the secondary fuse to blow.

If one or both fuses continue to blow after being replaced and the problem

cannot be determined, have the jack electrical system inspected and

repaired by an Enerpac authorized service center.

Motor brushes worn.

(single-phase models only)

Have motor brushes replaced by Enerpac authorized service center.

Loose connections or incorrect wiring.

Have electrical system inspected by Enerpac authorized service center.

Motor and/or electrical components worn

or damaged.

Have electrical system inspected by Enerpac authorized service center.

Repair or replace components as required.

8. Pump motor turns in

wrong direction.

(three-phase models

only)

Wiring incorrect.

Reverse electrical leads.

9. Pump motor runs hot

or trips circuit breaker.

(single-phase models)

Pump motor runs hot

or trips motor overload

relay. (three-phase

models)

Motor worn or damaged.

Have motor inspected by Enerpac authorized service center. Repair or

replace as required.

Motor is single phasing.

(three-phase models only)

Correct electrical wiring.

Pump element damaged, worn or seized.

Have pump element inspected by Enerpac authorized service center.

Repair or replace as required.

10. Pump motor tries to

start but will not run.

Low voltage.

Check AC line voltage.

Pump element jammed.

Have pump element inspected by Enerpac authorized service center.

Repair or replace components as required.

Motor and/or electrical components worn

or damaged.

Have electrical system inspected by Enerpac authorized service center.

Repair or replace components as required.

11. Jack is difficult to roll

on wheels.

Low tire inflation pressure.

Check tire inflation pressure. Add air if low.
Pressure should be 90 psi [6,2 bar].

Wheel bearings need lubrication.

Apply grease to wheel bearings.

Wheel locknut out of adjustment.

Loosen locknut until wheel rotates freely.

Advertising