Enerpac PR-Series Electric Benutzerhandbuch

Seite 3

Advertising
background image

3

If an extension cord is used:
1) The marked electrical rating of the extension cord should be at

least as great as the electrical rating of the jack.
2) The extension cord should be a grounding-type 3-wire cord

for single-phase power or a grounding type 4-wire cord for three

phase power.
3) A long extension cord should be arranged so that it will not

drape over any working area where it can be tripped over,

snagged, or pulled on unintentionally.

If the jack is to be operated outdoors and an extension cord is

needed, use only an outdoor-use extension cord. An outdoor-use

extension cord will be clearly marked with the suffix letter “W”

and the statement “Suitable for Use with Outdoor Appliances.”

ADDITIONAL PRECAUTIONS

WARNING: Do not use electric jacks in an explosive

atmosphere. Sparks and electrical arcing could ignite

combustible vapors or airborne dust.

IMPORTANT: To prevent damage to the jack electric motor,

check power specifications on jack or motor data plate. Use of

incorrect outlet will damage the motor.

3.0 PRODUCT DATA

Table 1 - General Specifications

Maximum Operating Pressure

Model

psi

bar

PREM_060_ _L

6,000

414

PREM_100_ _L

9,700

669

PREM_150_ _L

10,200

703

PREM_200_ _L

10,200

703

Load Rating

Model

US Tons

Metric Tons

kN

PREM_060_ _L

60

54

533

PREM_100_ _L

100

90

889

PREM_150_ _L

150

136

1333

PREM_200_ _L

200

181

1778

Hydraulic Oil Type

Enerpac HF (Refer to Table 8 for oil specifications chart)

Maximum Hydraulic Oil Temperature

170 ºF [76 °C]

Hydraulic Reservoir Oil Capacity

(approximate - when filled to

proper level)

4.2 gallons [15,9 liters]

Power Requirements

Model Number Beginning With:

Volts AC

Hz

Phase

Maximum

Current Draw

(Amperes)

PREMB

115

50-60

1

17.0

PREMI (North American Plug)

230

50-60

1

9.0

PREME (European Plug)

230

50-60

1

9.0

PREMG

208-240

50-60

3

8.0

PREMW

380-415

50-60

3

4.8

PREMJ

440-480

50-60

3

4.0

PREMR

575

50-60

3

3.2

Table 2 - Stroke Lengths and Weights

Short Stroke

Models

Stroke Length

Weight

Long Stroke

Models

Stroke Length

Weight

inches

mm

Pounds

Kg

inches

mm

Pounds

Kg

PREM_06014L

14

356

390

177

PREM_06027L

27

686

600

272

PREM_10016L

16

406

510

231

PREM_10027L

27

686

600

272

PREM_15016L

15.5

394

570

258

PREM_15027L

26.5

673

708

321

PREM_20016L

15.5

394

639

290

PREM_20027L

26.5

673

825

374

Notes: Weights shown above are approximate. Refer to Enerpac catalog for product external dimensions.