Enerpac PR-Series Electric Benutzerhandbuch

Seite 7

Advertising
background image

PRS Series spacers allow additional fine adjustment of the

extension stack height. They may be used alone or in conjunction

with PRE Series extensions.

Table 4 - PRS Series Spacers (optional accessories)

Spacer Model

Thickness (each)

inches

mm

PRS1

1

25

PRS2

2

51

PRS3

3

76

PRS4 Spacer Set

Set includes PRS1, PRS2 and PRS3 (1 each).

WARNING: Never exceed the maximum additional

stack height for your jack model. Refer to Table 5 for

additional information.

WARNING: Failure to observe the following instructions

could allow load to shift or drop. Serious personal injury

and/or property damage may result.

When using PRE Series extensions and/or PRS Series spacers,

always obey the following rules:
• For loads up to 60 tons [54 metric tons]: Any two PRE Series

extensions may be included in the stacking arrangement,

provided that the maximum stack height (See Table 5) is not

exceeded and the following exceptions are observed:

1) Jack models PREMB06014L, PREMI06014L and

PREME06014L: Only one PRE18 extension can be included

in the stacking arrangement.

2) All jack models ending in “16L”: Only one PRE11,

PRE14 or PRE18 extension can be included in the stacking

arrangement.

3) All jack models ending in “27L”: Extensions PRE14 and

PRE18 cannot be included in the stacking arrangement.

These extensions are designed for short stroke jacks only

(models ending in “14L” and “16L”).

• For loads over 60 tons [54 metric tons], or strokes over 14

inches [356 mm]: Only one PRE Series extension and one PRS

Series spacer can be included in the stacking arrangement.

• Never exceed 3 inches [76 mm] in total spacer height.
• Never exceed the maximum additional stack height for your

jack model. Refer to Table 5, dimension “X”.

Table 5 - Maximum Additional Stack Height Using

Optional PRE Series Extensions and PRS Series Spacers

Jack

Model

Maximum Additional Stack

Height (dimension “X”)

X

inches

mm

PREM_06014L

32

813

PREM_06027L

11

279

PREM_10016L

21

533

PREM_10027L

11

279

PREM_15016L

21

533

PREM_15027L

11

279

PREM_20016L

21

533

PREM_20027L

11

279

Note: Fifth letter of model will be B, E, I, G, W, J

or R, depending on jack electrical configuration.

Important: Refer to

Table 5 for maximum

additional stack height

information.

PRS Series Spacer

(see Table 4)

Load Cap

(see Table 6)

PRE Series

Extension

(see Table 3)

Cylinder Rod

Figure 5, Extension and Spacer Installation (typical)

5.7 Load Caps

A non-swivel load cap is included with the jack as standard

equipment. A swivel load cap is available as an optional

accessory. Refer to Table 6 for a list of load cap model numbers.

IMPORTANT: Use a swivel load cap to properly engage angled

lifting points. A swivel load cap should always be used when the

amount of misalignment between the standard load cap and the

lifting point is too large to be compensated for by use of plywood

or other suitable high-friction compression material alone.

Table 6 - Load Caps

Jack Model

Load Cap Model Numbers

Non-Swivel Load

Cap (standard)

Swivel Load Cap

(optional accessory)

PREM_06014L

42208E

PRTS60

PREM_06027L
PREM_10016L

42208E

PRTS60

PREM_10027L
PREM_15016L

42208E

PRTS150

PREM_15027L
PREM_20016L

42208E

PRTS200

PREM_20027L

Note: Fifth letter of model will be B, E, I, G, W, J or R, depending on

jack electrical configuration.

7