5.8 U-Ring Stacking Instructions

(See Figure 6)

Pow'r-Riser U-Rings (optional accessories) allow positive

mechanical load holding of a lifted load. The U-Rings are placed

on top of the cylinder housing and around the extended cylinder

rod. They are available in five different lengths for each Pow'r-

Riser model.
To help ensure proper alignment and installation, the top surface

of the cylinder housing and the top surface of each U-Ring

contains a raised locator. The bottom surface of each U-Ring

contains a mating recess.
The U-Rings are made of steel and aluminum. A steel U-Ring

must always be positioned at the top and bottom ends of the

U-Ring stack. The aluminum U-Rings must always be located

in the middle of the stack, between the two steel U-Rings. This

stacking arrangement helps prevent damage to the aluminum

U-Rings.

CAUTION: Never position an aluminum U-Ring at the

top or bottom end of the U-Ring stack.

Install U-Rings as described in the following steps:
1. Using the jack, raise the load to the desired lifting height.

Refer to the instructions in Section 5.5 of this manual.

2. Place one steel U-Ring on top of the cylinder housing,

around the extended cylinder rod.

3. As required, place one or more aluminum U-Rings on top

of the steel U-Ring, around the extended cylinder rod.

The quantity of aluminum U-Rings to be installed will vary,

depending on jack model, lifting height and the U-Ring set

being used. Refer to Table 7 for additional information.

4. Place a second steel U-Ring at the top of the U-Ring stack.

IMPORTANT: Be sure the arrow on each U-Ring is pointing up.

Be sure all locators are fully engaged in the mating recesses of

the U-Rings.

WARNING: Pinch point hazard: In the following step,

keep hands and fingers clear of area between load

support ring and top of U-Ring stack.

5. Slowly lower the cylinder rod until the weight of the load

is supported by the U-Rings. Refer to the information in

Section 5.5 for jack operating instructions.

IMPORTANT: Follow all applicable work rules and regulations

in effect at your facility or worksite. The use of auxiliary stands,

blocking or other additional load supports may be required even

when U-Rings are installed.

Assembled View

Load

Support

Ring

Load

Cap

Steel U-Ring

(top)

Recess of U-Ring

Steel U-Ring

(bottom)

Aluminum U-Rings

Locator (on each

U-Ring and at

top of cylinder

housing)

Figure 6, U-Ring Stacking Arrangement (typical)

Table 7 - U-Ring Information

Jack Model

U-Ring Size and Model Number

U-Ring

Set Model

Number

Items Included in Each U-Ring Set

1 inch

[25 mm]

3 inch

[76 mm]

4-1/2 inch

[114 mm]

5-1/2 inch

[140 mm]

10 inch

[254 mm]

2x

1x

2x

1x

PREM_06014L

PRU11

PRU13

PRU14

-

PRU110

PRUS126

PRU11

PRU13

PRU14

-

PREM_06027L

PRU11

PRU13

PRU14

-

PRU110

PRUS137

PRU11

PRU13

PRU14

PRU110

PREM_10016L

PRU11

PRU13

PRU14

-

PRU110

PRUS126

PRU11

PRU13

PRU14

-

PREM_10027L

PRU11

PRU13

PRU14

-

PRU110

PRUS137

PRU11

PRU13

PRU14

PRU110

PREM_15016L

PRU151

PRU153

-

PRU155

PRU1510

PRUS1526

PRU151

PRU153

PRU155

-

PREM_15027L

PRU151

PRU153

-

PRU155

PRU1510

PRUS1537

PRU151

PRU1510

PRU155

-

PREM_20016L

PRU201

PRU203

-

PRU155

PRU1510

PRUS2026

PRU201

PRU203

PRU205

-

PREM_20027L

PRU201

PRU203

-

PRU155

PRU1510

PRUS2037

PRU201

PRU2010

PRU205

-

Note: Fifth letter of model will be B, E, I, G, W, J or R, depending on jack electrical configuration.

Advertising