c. Solenoid valve has a

manual override (1).
Valve can be manually
shifted in either
direction, when needed.

4.

Dump Pump - PED/WED Models
a.

Switch

1. Power to pendant.

2. OFF

3. ON (Motor runs, cylinder will

advance.) To retract cylinder,
press top of switch (1).

b. Valve Operation (no external handle)

1. Press pendant switch to start motor

and advance cylinder.

2. Release pendant switch to shut off

motor and retract cylinder.

5.

Pressure Switch Pumps -

PES/WES Models

a. Switch

1. ON

2. OFF

3. OFF

b. Valve operation

1. Valve handle moves to control oil flow.

2. Pump runs until reaching preset pressure.

PES models = 10,000 psi

WES models = 5,000 psi

3. P r e s s u r e

a d j u s t m e n t –
refer to switch
and valve
a d j u s t m e n t
section.

7.0 ADJUSTMENTS

1.

Relief Valves (External)

Factory set at 10,000 psi or 5,000 psi depending on pump
models.

a. Install a gauge and fitting in pump port.

b. With system hoses and cylinders connected, run pump.

c. Turn adjusting set screw counter-clockwise to decrease

pressure.

d. Check setting by running two or three complete cycles.

2.

Pressure Switches

a. Adjust pressure settings.

5,000 psi model

1. Adjustable range is 3,000-5,000 psi.

2. Remove switch cover.

3. To change set point, turn hex on base of plunger.

4. Run pump. Observe gauge to check pressure settings.

Re-adjust switch until desired limits are obtained.

5. Re-install switch cover.

Gauge Port

Relief Valve

Decrease

Increase

Adjusting

Set Screw

15 amp SPDT

switch output

Stainless steel plunger

with self-locking

adjusting thread

Set point adjustment

Mounting bracket for installation of
enclosed types in any position.

Retract

Advance

ENERPAC

1

1

1

2

3

ADV

RET

1.

2.

1

2

3

3-way, 2-postion valve shown.

Other valves are available.