8.2 Hydraulic System

1.

Return line filter.

a. Check and clean every 150 hours of operation. Replace if

clogged or damaged.

b. To replace, unplug motor power cord, remove control valve

and connectors.

c. Lift filter canister out of cover.

d. Grasp canister with vise grip. Insert a 3/8" Allen wrench

into top hex and unthread top. Remove filter element and
clean or replace.

e. Re-assemble filter canister. Check o-ring. Place canister

into cover plate and install the control valve and
connectors.

NOTE: Pumps with heat exchangers: Filter canister cannot be

totally removed from coverplate. Leave partially in
cover, grip canister and use 3/8" Allen wrench to
remove the top. Remove filter element, clean or
replace filter. Reassemble filter canister.

2.

Changing Hydraulic Oil

a. Drain oil and fill with new oil every 300 hours of operation.

b. To drain oil, remove the fill plug. Tip the pump and drain oil

out of fill opening.

c. Re-fill reservoir with ENERPAC hydraulic oil. Use of any

other oil or fluids could damage the pump, seals and
hydraulic system components.

3.

Storing the Pump

a. Thoroughly clean the pump.

b. Drain oil and fill with new oil. Install plugs in all ports.

c. Cover the pump and store in a clean, dry location.

Fill Cap

Plug in
ports

Oil level
indicator