Enerpac PE-Series Benutzerhandbuch

Seite 7

Advertising
background image

7

b. Adjust pressure settings.

10,000 psi model

1. Loosen setscrew with No. 10 Allen wrench.

2. Using a screwdriver, turn adjustment screw clockwise to

raise and counter-clockwise to lower actuation point.

3. Tighten setscrew.

4. Run pump to verify pressure.

3.

Thermal Relay

1. A thermal relay monitors oil temperature.

2. Motor will be shut off if oil temperature exceeds 190°-195°F.

3. Allow oil to cool. Press "reset" button to operate pump.

8.0 MAINTENANCE

8.1 Fuses

1.

Main circuit board and solenoid protection.

Mounted on board:

115V models, 2 amp fuse;

230V models, 1 amp fuse

2.

Line fuse located in the side of shroud.

Protects complete electric circuit.

Size: 115V models - 20 amp

230 V models - 10 amp plus an in-line 10 amp fuse to protect
pump motor.

SPECIFICATIONS

5,000 psi Pump (WES Models)

10,000 psi Pump (PES Models)

Pressure switch Model No. IC51

Pressure switch Model No. IC72

NEMA 1 Classification

NEMA 12 Classification

Pressure range: 3,000-5,000 psi

Pressure range: 700-10,000 psi

Maximum Differential: 350-800 psi

Maximum Differential: 115-550 psi

Electrical: 5 Amps at 125 VAC

Electrical: 10 Amps at 125 VAC
250 VAC or 480 VAC

Adjusting slot

Lock screw

Fuse

Reset

Fuse

In-line 230V

fuse holder

Advertising