Cam designer professional – Lenze Cam Designer Professional getting started Benutzerhandbuch

Seite 71

Advertising
background image

Cam Designer Professional

L

69

Cam Designer Professional DE/EN 2.0

Functions provided for working in Interpolation Mode:

View

Interpolation Mode

Switch to Interpolation Mode (level 3).

Edit

Start Calculation

Open the Optimized Linear Interpolation dialog box to generate

a table of points:

Proceed as follows:

Number of Points 1. Go to the Number of Points field and select the number of

value pairs between 10 and 1024.

Optimize 2. The following steps are required for the optional

optimisation process:

– Go to the

Optimization Steps field and select the

required number of optimisation steps between 1000

and 10000.

– Click

Optimize to automatically calculate the optimal

distribution of points with the help of a neuron network

(artificial intelligence).
The progress of the error functions for minimum,

average and maximum errors is shown during the

optimisation process. The aim of optimisation is to

ensure that all three error values are low and more or

less the same.
After the optimisation has been completed, the number

of equidistant points which would be required to achieve

the same quality of movement will be indicated.

OK 3. Click OK to generate the value pairs and close the dialog

box.

File

GDC Export...

Export the calculated value pairs to Global Drive Control.

Show/Hide Bookmarks

Advertising