Troubleshooting

Problem

Possible Cause

Error correction

Device doesn‘t start

Emergency stop switch (5) has

been triggered

Reactivate the emergency stop

switch (5) by turning it. Press

the on switch (2) to restart the

device

No mains voltage

Main circuit breaker is tripped

Check the socket, mains supply

cable, cord, mains plug; if ne-

cessary, have them repaired by

a qualified electrician.

Check the main fuse

On/off switch (2/1) is broken Repair by Customer Care
Motor faulty

Repair by Customer Care

Strong vibrations

Motor unit (14) not fixed in

place

Check V-belt tension and tighten

the locking screw (13)

Bit not centrally clamped

Check the bit in the drill chuck

(4)

Loud squeaking noise

V-belt tension is too high

Check V-belt tension

Damaged V-belt (26)

Check V-belt (26)

Damaged pulley

Check pulleys