Repacking the Printer

magicolor 6100 DeskLaser User's Guide

7-6

1

With the printer’s top cover
open, at the top of the fuser,
rotate the two lock levers to
release the oil bottle.

2

Remove the oil bottle.



Caution: Hold a sheet of paper under the
oil bottle as you remove it, so no oil drips
into the printer.

3

Turn the knob on the opening on the bottom clockwise
to close it. Place the oil bottle (knob up) in an oil-proof
container such as a plastic bag, until you’re ready to
reinstall it.

4

Use the fuser oil remover syringe that came with your
printer or an eye-dropper to remove any excess oil
from the printer.

»

Note: Dispose of the oil in accordance with local safety laws and regulations.