Burkert Type 8625 Benutzerhandbuch
Seite 4

Technic
General
for cont
Operating
Power con
Output cu
Operating
Interferenc
Interferenc
Output
Cable out
Number o
Type of co
Housing
Degree of
Material
Mounting
Dimension
Inputs
Signal inp
Accurac
Type of
1 Standar
Connec
Controlle
Control al
Sampling
Amplificat
integral ac
K-factors
Ratio
Calibratio
Device O
Control u
Application areas and function
Safety notes
ATTENTION!
• Observe the general technical regulations when planning
application and operation of the unit!
• Take precautions to avoid inadvertent actuation or
unwanted interference!
• Pipelines and valves under pressure must not be
disconnected!
• Always isolate the voltage supply before working on the
system!
• If this instruction is not followed, or if any inadmissible
tampering with the appliance takes place, we will accept no
further liability, and the guarantee on the appliance and its
accessories will become invalid!
ATTENTION
EXERCISE CAUTION ON HANDLING!
ELECTROSTATICALLY SENSITIVE
COMPONENTS / MODULES
This device contains electronic components that are sensitive to
electrostatic discharge (ESD). Contact to electrostatically
charged persons or objects will endanger these components. In
the worst case, they will be immediately destroyed or will fail after
commissioning. Observe the requirements of EN 100 015 - 1 in
order to minimize the possibility of, or avoid, damage from
instantaneous electrostatic discharge. Also take care not to touch
components that are under supply voltage.
NIEDERLASSUNGEN / BRANCH OFFICES
Operating Instructions 0606/04_EU-ML_00804590
To ensure the devices function correctly, and have along
service life, please comply with the information in these
Operating Instructions, as well as the Applications Conditions and
the permissible values specified in the data sheets for the propor-
tional valves used, and the types 8623-2, 8624-2 or 8625-2
controller.
The quickstart foldout is a supplement to the Operating
Instructions. More detailed information is to be found on the
enclosed CD.
GENERAL NOTES
FUNCTION
TECHN
We reserve the right to make technical changes without notice.
This family of miniature controllers, in combination with
proportional valves, serves to control
• Liquid flow in piping
(Flow rate controller 8623)
• Pressure in liquids and
(Pressure controller 8624)
flowing gases
• Mixing temperature of
(Temperature controller 8625)
two media
• Suitable for proportional valves
types 6022, 6023, 6223, 2832, 2834
• Controller with adjustable PI control behaviour
• Direct installation on the valve, thanks to compact design of
device
• Direct actuation of a proportional valve
• Scaling
• Setpoint specification via standard signal 4-20 mA
• Measurement of flow rate by means of a flow rate sensor with
frequency output (frequency proportional to flow rate)
• For flow rate sensors with frequency output of max. 625 Hz
• Programming and display control unit Type 8623-B
• Proportional control
• Measurement of the pressure by means of a pressure
transmitter with standard output signal
• Programming and display control unit Typ 8624-B
• Measurement of the temperature by means of a PT 100 sensor
• Heating / cooling
• Programming and display control unit Typ 8625-B
8623
8624
8625
Chr.-Bürkert-Straße 13-17
Berlin
Ph: (0 30) 67 97 17 - 0
74653 Ingelfingen
Dortmund
Ph: (0 23 73) 96 81 - 0
Ph: (0 79 40) 10-111
Frankfurt
Ph: (0 61 03) 94 14 - 0
Fax (0 79 40) 10-448
Hannover
Ph: (05 11) 9 02 76 - 0
www.buerkert.com
München
Ph: (0 89) 82 92 28 - 0
Stuttgart
Ph: (07 11) 4 51 10 - 0
BÜRKERT INTERNATIONAL
A
Ph. +43 (0)1-894 13 33
Fax
+43 (0)1-894 13 00
AUS Ph. +61 1300 888 868
Fax
+61 1300 888 076
B
Ph. +32 (0)3-325 89 00
Fax
+32 (0)3-325 61 61
BRA Ph. +55 (0)11-5182 0011
Fax
+55 (0)11-5182 8899
CDN Ph. +1 905-847 55 66
Fax
+1 905-847 90 06
C H
Ph. +41 (0)41-785 66 66
Fax
+41 (0)41-785 66 33
C N
Ph. +86 21-5868 21 19
Fax
+86 21-5868 21 20
C Z
Ph. +420 543-25 25 05
Fax
+420 543-25 25 06
D K
Ph. +45 44-50 75 00
Fax
+44-50 75 75
ES
Ph. +34 93-477 79 80
Fax
+34 93-477 79 81
EE
Ph. +372 6440 698
Fax
+372 6313 759
FI
Ph. +358 (0)207 412 550
Fax
+358 (0)207 412 555
F R
Ph. +33 (0)388-58 91 11
Fax
+33(0)388-57 20 08
HKG Ph. +852 248 012 02
Fax
+852 241 819 45
IT
Ph. +39 02-959 071
Fax
+39 02-959 07 251
IND
Ph. +91 (0)44-4230 3456
Fax
+91 (0)44-4230 3232
J
Ph. +81 (0)3-5827-0066
Fax
+81 (0)3-5827-0067
KOR Ph. +82 (0)2-3462 5592
Fax
+82 (0)2-3462 5594
NO
Ph. +47 63-84 44 10
Fax
+47 63-84 44 55
N L
Ph. +31 (0)346-58 10 10
Fax
+31 (0)346-56 37 17
N Z
Ph. +64 (0)9-622 28 40
Fax
+64 (0)9-622 28 47
P
Ph. +351 212 898 275
Fax
+351 212 898 276
PL
Ph. +48 (0)22-840 60 10
Fax
+48 (0)22-840 60 11
R C
Ph. +886 (0)2-2653 78 68
Fax
+886 (0)2-2653 7968
RP
Ph. +63 (0)2-776 43 84
Fax
+63 (0)2-776 43 82
SE
Ph. +46 (0)40-664 51 00
Fax
+46 (0)40-664 51 01
SA
Ph. +27 (0)11-574 60 00
Fax
+27 (0)11-454 14 77
SIN
Ph. +65 6844 2233
Fax
+65 6844 3532
T R
Ph. +90 (0)232-459 53 95
Fax
+90 (0)232-459 76 94
TT
Ph. +60 (0)4-643 5008
Fax
+60 (0)4-643 7010
U K
Ph. +44 (0)1453-73 13 53
Fax
+44 (0)1453-73 13 43
USA Ph. +1 949-223 31 00
Fax
+1 949-223 31 98
Contact addresses / Kontaktadressen
Germany / Deutschland / Allemange
Bürkert Fluid Control System
Sales Centre
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail:
International
Contact addresses can be found on the internet at:
Die Kontaktadressen finden Sie im Internet unter:
Les adresses se trouvent sur internet sous :
www.burkert.com Bürkert / Company / Locations