Festo Неполноповоротные приводы DRQD-6...12 Benutzerhandbuch

Seite 34

Advertising
background image

DRQD-6/ ... /12-...

Festo DRQD-6/ ... /12-... 0109a English

34

The maximum permitted

lateral force Fy (static and dynamic) as a factor of dis-

tance Z is shown in Fig. 18.

Fig. 18

Fy stat. = Static lateral force
Fy dyn. = Dynamic lateral force
Z = Distance

If combined loads occur, make sure that the individual values fulfil the following
inequation:

F

x

F

x max

+

F

y

F

y max

≤ 1

The

maximum mass moment of inertia for the DRQD-... is shown in the following

table.

Size

Maximum mass moment of inertia for DRQD-... *)

DRQD-6-...

0.075 x 10

-4

kgm

2

DRQD-8-...

0.25 x 10

-4

kgm

2

DRQD-12-...

0.7 x 10

-4

kgm

2

*) Unrestricted

Fig. 19