DRQD-6/ ... /12-...
Festo DRQD-6/ ... /12-... 0109a English
34
The maximum permitted
lateral force Fy (static and dynamic) as a factor of dis-
tance Z is shown in Fig. 18.
Fig. 18
Fy stat. = Static lateral force
Fy dyn. = Dynamic lateral force
Z = Distance
If combined loads occur, make sure that the individual values fulfil the following
inequation:
F
x
F
x max
+
F
y
F
y max
≤ 1
The
maximum mass moment of inertia for the DRQD-... is shown in the following
table.
Size
Maximum mass moment of inertia for DRQD-... *)
DRQD-6-...
0.075 x 10
-4
kgm
2
DRQD-8-...
0.25 x 10
-4
kgm
2
DRQD-12-...
0.7 x 10
-4
kgm
2
*) Unrestricted
Fig. 19
Advertising