Avoid situations where loads are not directly centered
on the cylinder plunger. Off-center loads produce
considerable strain on cylinders and plungers. In
addition, the load may slip or fall, causing potentially
dangerous results.
Distribute the load evenly across the
entire saddle surface. Always use a
saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must
only be serviced by a qualified hydraulic
technician. For repair service, contact the
Authorized ENERPAC Service Center in your area.
To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or
damaged parts by genuine ENERPAC
parts. Standard grade parts will break
causing personal injury and property damage.
ENERPAC parts are designed to fit properly and
withstand high loads.
SPECIFICATIONS
5,000 PSI Models
10,000 PSI Models
Flow vs Pressure
150 cu. in./min at 0 - 1,000 psi
40 cu. in./min at 1,000 - 5,000 psi
20 cu. in./min at 1,000 - 10,000 psi
Motor Voltage
B models - 115V, 1 phase, 50/60 cycle
D models - 115V, 1 phase, 50/60 cycle with heat exchanger
E models - 230V, 1 phase, 50/60 cycle
F models - 230V, 1 phase, 50/60 cycle with heat exchanger
Amperage Draw
13.5 Amps at maximum pressure @ 115 volts
6.75 Amps at maximum pressure @ 230 volts
Relief Valve
1,000 psi to 5,000 psi
1,000 psi to 10,000 psi
Adjustment Range
Oil Capacity
1.75 gal. total - 1.5 gal.
useable
1.75 gal. total - 1.5 gal useable
Pressure Switches
• NEMA Classification
NEMA 1
NEMA 13
• Pressure Range
500 - 5,000 psi
700 - 10,000 psi
• Max. Differential
50 - 400 psi
115 - 500 psi
DBA
62 - 78
62 - 78
3
/
8
"-18NPTF
5
406
185
50
126
213
227
239
284
179
101
196
91
98
ø 4
182
56
25
38
PUMP EXTERIOR DIMENSIONS
Dimensions are in inches.
.185-.195 dia. (4 places) holes for self-tapping screws.
① Heat exchanger (optional for all models)
➁ Fill port
➂ Pressure switch (PES-series, optional for all other models)
④ Oil lever indicator
⑤ Adjustable relief valve
0
Pressure (psi)
➔
Oil flo
w (in
3
/min)
➔
5000
4000
3000
2000
1000
0
200
150
100
50
5,000 psi Flow chart
Submerged Pump – Flow characteristics
Flow (in
3
/min)
Pressure (psi)
10,000 psi Flow chart
Submerged Pump – Flow characteristics
Flow (in
3
/min)
Pressure (psi)