Operating instructions safety switches nx...as, Status table – EUCHNER NXxxxAS1 Benutzerhandbuch
Seite 6

Operating Instructions Safety Switches NX...AS
1
Figure 4: Dimension drawing NX...AS1, insertion depth and approach radii
R
R
R
42
s
s
RD
GN
LED
51,5
46
58,5
39
19
25,5
160
4,5
21,5
8,5
4,5
C
B
D
A
Standard
D
Insertion depth
for M5 > 45 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
Inser
tion depth
Order actuator separately
Actuator Insertion depth s Approach radius R
Standard
32 + 1
> 300
Overtravel
32 + 8
> 440
Plug connector
not aligned
Hinged actuator X-LR-N
Actuator type
Door radius min. [mm]
ACTUATOR-X-GQ
300
ACTUATOR-X-WQ
ACTUATOR-X-GNQ
440
ACTUATOR-X-WNQ
R >
100
7
21
30
45
32+8
8,8
21,5
Ø 5,5
40
R>100
*=R
5,1
51
4
23
29
50
Hinged actuator X-OU-N
Status table
Programming
State
D0, D1
D2, D3
Monitor diagnosis
Green
Safety guard closed
Code sequence
If start-up test selected:
yellow flashing on start-up
2-channel
Intermediate state during opening or closing
dependent
of the safety guard.
Half-seq.
00
During opening: yellow flashing
Synchronization time
Switch S1 (internal) open
During closing: red
3 s
Intermediate state during opening or closing
After expiration of the synchronization time:
of the safety guard.
00
Half-seq.
yellow flashing
Switch S2 (internal) open
Safety guard open
00
00
Red
Address 0 or communication disrupted
–
Gray