Operating Instructions Safety Switches TP...AS

1

Figure 3: Dimension drawing

35

3,

5

30

40

144

192

31

22

16

16

43

8,5

3,5

h

42

14

v

M20x1,

5 (

2

x)

GN RD

Power Fault

For M5 > 35 mm
ISO 1207 (DIN84)
ISO 4762
(DIN 912)
M = 1.5 Nm

Mechanical release

M = 0.5 Nm

Locking screw

M = 0.6 Nm

Figure 4: Min. door radii

Actuator type

Door radius min. [mm]

Actuator P-G...

1,000

Actuator P-W...

1,000

HINGED ACTUATOR P-OU...

90

HINGED ACTUATOR P-LR...

100

Hinged actuator P-OU / P-OUN

12

26

20

35

28

+2

R >

9

0

Hinged actuator P-LR / P-LRN

R >

100

Technical data

Parameters

Value

Housing material

Reinforced
thermoplastic

Degree of protection
acc. to IEC 529

IP 67, mating connector plugged

Mechanical life

1x10

6

operating cycles

Ambient temperature

-20 ... +55°C

Installation position

Any

Approach speed, max.

20 m/min

Actuating force

10 N

Extraction force

20 N

Retention force

10 N

Locking force F

max

F

max

= 1,300 N

Locking force F

Zh

in acc. with GS-ET-19
Weight

Approx. 0.5 kg

Switching principle SK, ÜK

Positively driven, slow-action
switching contact

EMC protection requirements Acc. to EN 50295 (AS-Interface

standard) and IEC 62026

Interlocking solenoid
Solenoid operating voltage

DC 24 V +10%/-15%

8 W

(auxiliary power on black

Power supply unit with safe isolation

AS-Interface line)

(IEC 60742, PELV)

Solenoid operating current

300 mA

Duty cycle

100%

Connection

M12 plug connector

Minimum travel and overtravel
Approach direction

Actuator

Actuator

Standard

Overtravel

Horizontal (h)

28 + 2

28+7

Vertical (v)

29.5 + 1.5

AS-Interface data acc. to

EA code: 7

AS-Interface specification 2.1 ID code: B
Operating voltage AS-Interface DC 22.5 ... 31.6 V
Total current consumption, max. 45 mA
Valid AS-Interface addresses

1 - 31

AS-Interface inputs

Acc. to AS-Interface Safety at Work

Door monitoring contact SK

D0, D1

Solenoid monitoring contact ÜK D2, D3
AS-Interface outputs
D0

Guard locking solenoid,
1 = solenoid energized

D1

Red LED, 1 = LED on

D2

Green LED, 1 = LED on

AS-Interface LED Power

Green, AS-Interface voltage present

AS-Interface LED Fault

Red, offline phase or address 0

Reliability values according to EN ISO 13849-1
B

10d

3 x 10

6

(F

Zh

=

F

max

) = 1000 N

1,3