Operating instructions safety switches sgp..as1 – EUCHNER SGPxxAS1 Benutzerhandbuch
Seite 6

Operating Instructions Safety Switches SGP..AS1
0,3 B
V
<40>
30
31
3
Ø4,1
M=0,6 Nm
Ø5,1
h
0,3 A
16
9
4
M=0,6 Nm
<41,5>
<35,5>
32
16
42
13
30
22
4
123
A
A-A
Power
Fault
A
A
Figure 4: Dimension drawing
Insertion depth
Fixed positioning
for safety-related
applications
(screw M5)
Inser
tion depth
Plug connector
not aligned
Order actuator separately
Necessary minimum travel + permissible overtravel [mm]
Approach direction
Actuator
S
Actuator
L
Standard
Insertion funnel
Horizontal (h)
24.5 + 5
28.5 + 5
Vertical (v)
24.5 + 5
28.5 + 5
Figure 5: Min. door radii
Actuator type
Door radius min. [mm]
Actuator S-G...
300
Actuator S-W...
300
HINGED ACTUATOR S-OU...
200
HINGED ACTUATOR S-LR...
200
Hinged actuator S-OU-LN
for insertion funnel
Hinged actuator S-LR-LN
for insertion funnel
16
30
R >
200
35,5
4
28,5 +5
20
R>200
Hinged actuator S-OU-SN
Hinged actuator S-LR-SN
24,5 +5
12
26
35,5
R >
20
200
R>200