Operating instructions safety switches sgp..as1 – EUCHNER SGPxxAS1 Benutzerhandbuch

Seite 6

Advertising
background image

Operating Instructions Safety Switches SGP..AS1

0,3 B

V

<40>

30
31

3

Ø4,1

M=0,6 Nm

Ø5,1

h

0,3 A

16

9

4

M=0,6 Nm

<41,5>

<35,5>

32

16

42

13

30

22

4

123

A

A-A

Power

Fault

A

A

Figure 4: Dimension drawing

Insertion depth

Fixed positioning
for safety-related
applications
(screw M5)

Inser

tion depth

Plug connector
not aligned

Order actuator separately

Necessary minimum travel + permissible overtravel [mm]

Approach direction

Actuator

S

Actuator

L

Standard

Insertion funnel

Horizontal (h)

24.5 + 5

28.5 + 5

Vertical (v)

24.5 + 5

28.5 + 5

Figure 5: Min. door radii

Actuator type

Door radius min. [mm]

Actuator S-G...

300

Actuator S-W...

300

HINGED ACTUATOR S-OU...

200

HINGED ACTUATOR S-LR...

200

Hinged actuator S-OU-LN

for insertion funnel

Hinged actuator S-LR-LN

for insertion funnel

16

30

R >

200

35,5

4

28,5 +5

20

R>200

Hinged actuator S-OU-SN

Hinged actuator S-LR-SN

24,5 +5

12

26

35,5

R >

20

200

R>200

Advertising