Operating instructions safety switches stp...as, Technical data, Figure 3: dimension drawing – EUCHNER STPxxxAS1 Benutzerhandbuch

Seite 7: Figure 4: min. door radii

Advertising
background image

Operating Instructions Safety Switches STP...AS

1

0,5

0,5

<40>

30

47

v

h

GN

RD

Power

45

144

41,5

35,5

16

<42>

190

13

4

30

16

4

Fault

9

Figure 3: Dimension drawing

for M5 > 35 mm
ISO 1207
ISO 4762
M = 1.5 Nm
Mechanical
release

M = 0.5 Nm

Locking screw

M = 0.6 Nm

Locking screw
M20 x 1.5

Technical data

Parameters

Value

Housing material

Reinforced
thermoplastic

Deg. of prot. acc. to IEC 529

IP 67, mating connector plugged

Mechanical life

1x10

6

operating cycles

Ambient temperature

-20 ... +55°C

Installation position

Any

Approach speed, max.

20 m/min

Actuating force

35 N

Extraction force

30 N (not locked)

Retention force

20 N

Locking force F

max

2,500 N

Locking force F

Zh

according to GS-ET-19
Weight

Approx. 0.5 kg

Switching principle SK, ÜK

Positively driven, slow-action switching
contact

EMC protection requirements

Acc. to EN 50295 (AS-Interface
standard) and IEC 62026

Interlocking solenoid
Solenoid operating voltage

DC 24 V +10%/-15%

8 W

(auxiliary power on black

Power supply unit with safe isolation

AS-Interface line)

(IEC 60742, PELV)

Solenoid operating current

300 mA

Duty cycle

100%

Connection

M12 plug connector

Minimum travel and overtravel
Approach direction

Actuator

S

Actuator

L for

standard

insertion funnel

horizontal (h) + vertical (v)

24.5 + 5

28.5 + 5

AS-Interface data acc. to

EA code: 7

AS-Interface specification 2.1

ID code: B

Operating voltage AS-Interface DC 22.5 ... 31.6 V
Total current consumption, max. 45 mA
Valid AS-Interface addresses

1 - 31

AS-Interface inputs

Acc. to AS-Interface Safety at Work

Door monitoring contact SK

D0, D1

Solenoid monitoring contact ÜK D2, D3
AS-Interface outputs
D0

Guard locking solenoid,
1 = solenoid energized

D1

Red LED, 1 = LED on

D2

Green LED, 1 = LED on

AS-Interface LED Power

Green, AS-Interface voltage present

AS-Interface LED Fault

Red, offline phase or address 0“

Reliability values according to EN ISO 13849-1
B

10d

5 x 10

6

Figure 4: Min. door radii

Actuator type

Door radius min. [mm]

Actuator S-G...

300

Actuator S-W...

300

HINGED ACTUATOR S-OU...

200

HINGED ACTUATOR S-LR...

200

Hinged actuator S-OU-LN

for insertion funnel

Hinged actuator S-LR-LN

for insertion funnel

16

30

R >

200

35,5

4

28,5 +5

20

R>200

Hinged actuator S-OU-SN

Hinged actuator S-LR-SN

24,5 +5

12

26

35,5

R >

20

200

R>200

(F

Zh

=

F

max

) = 2000 N

1,3

Advertising