Operating instructions safety switches stp...as, Technical data, Figure 3: dimension drawing – EUCHNER STPxxxAS1 Benutzerhandbuch
Seite 7: Figure 4: min. door radii

Operating Instructions Safety Switches STP...AS
1
0,5
0,5
<40>
30
47
v
h
GN
RD
Power
45
144
41,5
35,5
16
<42>
190
13
4
30
16
4
Fault
9
Figure 3: Dimension drawing
for M5 > 35 mm
ISO 1207
ISO 4762
M = 1.5 Nm
Mechanical
release
M = 0.5 Nm
Locking screw
M = 0.6 Nm
Locking screw
M20 x 1.5
Technical data
Parameters
Value
Housing material
Reinforced
thermoplastic
Deg. of prot. acc. to IEC 529
IP 67, mating connector plugged
Mechanical life
1x10
6
operating cycles
Ambient temperature
-20 ... +55°C
Installation position
Any
Approach speed, max.
20 m/min
Actuating force
35 N
Extraction force
30 N (not locked)
Retention force
20 N
Locking force F
max
2,500 N
Locking force F
Zh
according to GS-ET-19
Weight
Approx. 0.5 kg
Switching principle SK, ÜK
Positively driven, slow-action switching
contact
EMC protection requirements
Acc. to EN 50295 (AS-Interface
standard) and IEC 62026
Interlocking solenoid
Solenoid operating voltage
DC 24 V +10%/-15%
8 W
(auxiliary power on black
Power supply unit with safe isolation
AS-Interface line)
(IEC 60742, PELV)
Solenoid operating current
300 mA
Duty cycle
100%
Connection
M12 plug connector
Minimum travel and overtravel
Approach direction
Actuator
S
Actuator
L for
standard
insertion funnel
horizontal (h) + vertical (v)
24.5 + 5
28.5 + 5
AS-Interface data acc. to
EA code: 7
AS-Interface specification 2.1
ID code: B
Operating voltage AS-Interface DC 22.5 ... 31.6 V
Total current consumption, max. 45 mA
Valid AS-Interface addresses
1 - 31
AS-Interface inputs
Acc. to AS-Interface Safety at Work
Door monitoring contact SK
D0, D1
Solenoid monitoring contact ÜK D2, D3
AS-Interface outputs
D0
Guard locking solenoid,
1 = solenoid energized
D1
Red LED, 1 = LED on
D2
Green LED, 1 = LED on
AS-Interface LED Power
Green, AS-Interface voltage present
AS-Interface LED Fault
Red, offline phase or address 0“
Reliability values according to EN ISO 13849-1
B
10d
5 x 10
6
Figure 4: Min. door radii
Actuator type
Door radius min. [mm]
Actuator S-G...
300
Actuator S-W...
300
HINGED ACTUATOR S-OU...
200
HINGED ACTUATOR S-LR...
200
Hinged actuator S-OU-LN
for insertion funnel
Hinged actuator S-LR-LN
for insertion funnel
16
30
R >
200
35,5
4
28,5 +5
20
R>200
Hinged actuator S-OU-SN
Hinged actuator S-LR-SN
24,5 +5
12
26
35,5
R >
20
200
R>200
(F
Zh
=
F
max
) = 2000 N
1,3