Teaching in handle module, Preparing device for teach-in operation ì – EUCHNER MGB-AR(V2.0.0) Benutzerhandbuch
Seite 2

Quick Guide for Teach-in Operation – MGB-AP/MGB-AR (from V2.0.0)
Su
bj
ec
t t
o
te
ch
nic
al
m
od
ific
at
io
ns
; n
o
re
sp
on
sib
ilit
y
is
ac
ce
pt
ed
fo
r t
he
a
cc
ur
ac
y
of
th
is
inf
or
m
at
io
n.
©
E
UC
HN
ER
G
m
bH
+
C
o.
1
14
90
3-
01
-0
3/
12
(t
ra
ns
lat
io
n
of
th
e
or
ig
ina
l o
pe
ra
tin
g
ins
tru
ct
io
ns
)
EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]
Teaching in handle module
1. Insert bolt tongue into the evaluation module.
2. Switch on operating voltage UA and UB.
¨
In case of AR configuration: The green LED (State) flashes quickly (approx. 5 Hz).
A self-test is performed during this time (approx. 8 s).
¨
If the LED (DIA) is lit, there is a fault. Teach-in operation is not possible The green LED (State)
indicates the error code. For diagnostics, refer to the “System status table” in the respective
system manual.
3. Activate guard locking (only MGB-L1/MGB-L2).
MGB-L1: no voltage at IMP.
MGB-L2: voltage at IMP.
¨
Teach-in operation starts, green LED (State) flashes (approx. 1 Hz). The teach-in operation is
completed after approx. 60 seconds, the green LED (State) goes out.
4. Switch off operating voltage UB (at least 3 seconds).
¨
The code of the handle module that was just taught is activated in the evaluation module.
5. Switch on operating voltage UB.
¨
The device operates in normal mode.
Preparing device for teach-in operation
Ì
Connect the MGB as shown below, but do not connect voltage to UB yet.
Ì
Observe the different control of guard locking for MGB-L1 and MGB-L2
Note!
In case of AR configuration: FI1A and FI1B must be connected to DC 24 V for standby state
for teach-in . Every MGB should be taught-in individually prior to establishment of a switch chain.
UB
0V
UA
0V
-F2
-F1
/
/
DC 24 V
GND
MGB-L0...AP
UB
0V
UA
Fl
1A
Fl
1B
0V
-F2
-F1
/
/
DC 24 V
GND
MGB-L0...AR
UB
0V
UA
IM
P
0V
IM
M
-F2
-F1
/
/
DC 24 V
GND
MGB-L1...AP
UB
0V
UA
IM
P
Fl
1A
Fl
1B
0V
IM
M
-F2
-F1
/
/
DC 24 V
GND
MGB-L1...AR
UB
0V
UA
IM
P
0V
IM
M
-F2
-F1
/
/
DC 24 V
GND
MGB-L2...AP
UB
0V
UA
IM
P
Fl
1A
Fl
1B
0V
IM
M
-F2
-F1
/
/
DC 24 V
GND
MGB-L2...AR
6 5 4 3 2 1
6 5 4 3 2 1
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
optional cover function *
U
B
0V
O
I
O
L
O
T
O
D
R
S
T
FO
1B
FO
1A
*
FI
1B
FI
1A
U
A
0V
*
IM
P
IM
M
Terminal assignment
MGB-L1...AP (guard locking by spring force)
No voltage at IMP (guard locking active)
MGB-L1...AR (guard locking by spring force)
No voltage at IMP (guard locking active)
MGB-L2...AR (guard locking by solenoid force)
Voltage at IMP (guard locking active)
MGB-L2...AP (guard locking by solenoid force)
Voltage at IMP (guard locking active)