Teaching in handle module, Preparing device for teach-in operation ì – EUCHNER MGB-AR Benutzerhandbuch

Seite 2

Advertising
background image

Quick Guide for Teach-in Operation – MGB-AP/MGB-AR (from V2.0.0)

Su

bj

ec

t t

o

te

ch

nic

al

m

od

ific

at

io

ns

; n

o

re

sp

on

sib

ilit

y

is

ac

ce

pt

ed

fo

r t

he

a

cc

ur

ac

y

of

th

is

inf

or

m

at

io

n.

©

E

UC

HN

ER

G

m

bH

+

C

o.

1

14

90

3-

01

-0

3/

12

(t

ra

ns

lat

io

n

of

th

e

or

ig

ina

l o

pe

ra

tin

g

ins

tru

ct

io

ns

)

EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]

Teaching in handle module

1. Insert bolt tongue into the evaluation module.
2. Switch on operating voltage UA and UB.

¨

In case of AR configuration: The green LED (State) flashes quickly (approx. 5 Hz).

A self-test is performed during this time (approx. 8 s).

¨

If the LED (DIA) is lit, there is a fault. Teach-in operation is not possible The green LED (State)

indicates the error code. For diagnostics, refer to the “System status table” in the respective

system manual.

3. Activate guard locking (only MGB-L1/MGB-L2).

MGB-L1: no voltage at IMP.

MGB-L2: voltage at IMP.

¨

Teach-in operation starts, green LED (State) flashes (approx. 1 Hz). The teach-in operation is

completed after approx. 60 seconds, the green LED (State) goes out.

4. Switch off operating voltage UB (at least 3 seconds).

¨

The code of the handle module that was just taught is activated in the evaluation module.

5. Switch on operating voltage UB.

¨

The device operates in normal mode.

Preparing device for teach-in operation

Ì

Connect the MGB as shown below, but do not connect voltage to UB yet.

Ì

Observe the different control of guard locking for MGB-L1 and MGB-L2

Note!

In case of AR configuration: FI1A and FI1B must be connected to DC 24 V for standby state
for teach-in . Every MGB should be taught-in individually prior to establishment of a switch chain.

UB

0V

UA

0V

-F2

-F1

/

/

DC 24 V

GND

MGB-L0...AP

UB

0V

UA

Fl

1A

Fl

1B

0V

-F2

-F1

/

/

DC 24 V

GND

MGB-L0...AR

UB

0V

UA

IM

P

0V

IM

M

-F2

-F1

/

/

DC 24 V

GND

MGB-L1...AP

UB

0V

UA

IM

P

Fl

1A

Fl

1B

0V

IM

M

-F2

-F1

/

/

DC 24 V

GND

MGB-L1...AR

UB

0V

UA

IM

P

0V

IM

M

-F2

-F1

/

/

DC 24 V

GND

MGB-L2...AP

UB

0V

UA

IM

P

Fl

1A

Fl

1B

0V

IM

M

-F2

-F1

/

/

DC 24 V

GND

MGB-L2...AR

6 5 4 3 2 1

6 5 4 3 2 1

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

optional cover function *

U

B

0V

O

I

O

L

O

T

O

D

R

S

T

FO

1B

FO

1A

*

FI

1B

FI

1A

U

A

0V

*

IM

P

IM

M

Terminal assignment

MGB-L1...AP (guard locking by spring force)

No voltage at IMP (guard locking active)

MGB-L1...AR (guard locking by spring force)

No voltage at IMP (guard locking active)

MGB-L2...AR (guard locking by solenoid force)

Voltage at IMP (guard locking active)

MGB-L2...AP (guard locking by solenoid force)

Voltage at IMP (guard locking active)