Drive plc developer studio – Lenze DDS v2.1 Benutzerhandbuch
Seite 36

Drive PLC Developer Studio
L
34
DDS DE/EN 2.1
Channel creation with default parameters:
•
Select Communication parameter from the dialog box. Then click the entry
local host
➞
➞
➞
➞
Lenze standard and confirm the entry with OK.
Configuration “Lenze standard” (cannot be changed):
Settings:
standard:
Communciation driver:
CAN 8220 Lenze system bus dongle driver
Parameter:
Possible settings
Parameter channel:
1, 2, configurator
configurator
CAN bus node address:
1..63
CAN bus baud rate:
5, 10, 20, 50, 100, 125, 250, 500, 1000, configurator
configurator
Configuration “Lenze OPC” (cannot be changed):
Settings:
standard:
Communciation driver:
System bus server driver
Parameter:
Possible settings
CAN bus node address:
1..63
Channel creation with detected/desired parameters:
1. Click
New, to open the dialog box Communication parameter: New channel and to configure a
new channel.
2. The input field
Name already shows a name for the new channel. It is however possible to
change the name.
3. Select one entry e. g.
CAN 8220.
4. Confirm the selection with
OK.
5. Select the new channel and enter the corresponding communication parameters by using the
arrow keys.
6. Accept the settings with
OK.
Note!
If the establishment of a connection to a target system is faulty, please start the system bus
configuration tool.
Start
➞
➞
➞
➞
Program
➞
➞
➞
➞
Lenze
➞
➞
➞
➞
Communication
➞
➞
➞
➞
Systembus configuration tool
Select an adapter (e.g. 2173) and click
Dianostics in the register General.
Tip!
Confirm the function key
<F1> in the dialog box Communication parameter, to call the online help and
further information on the setting of communication parameters.