4.4.3

Log in the automation system

The car park program can be transferred to the automation system and started after the communication

parameters have been determined.

Tip!

If the PC is not connected to an automation system, the car park program can also be executed in the

Simulation Mode in DDS (only with the DDS Professional version):

Select

Online

Log in, to log in the automation system and change to the online mode.

(Also with activated simulation mode.)

After log in

all online functions in the menu

Online  are available.

the Declaration editor

‚ and the function plan editor ƒ of the organization unit Counter are

combined in a monitor window, i. e. the actual variable values are displayed and the Boolean

variables are highlighted (TRUE = blue, FALSE = black).



‚

ƒ

Warning!

For use of an automation system with motor control
(e. g. 9300 Servo PLC):

Do not use the commands

Controller enable/Controller inhibit for an emergency stop via PC, since

these commands are transferred to the controller with a delay.