5 teaching the oadm – Baumer BA OADM20x24 Benutzerhandbuch

Seite 30

Advertising
background image

BA_OADM20x24.doc

30/39

Baumer

05.12.12

Frauenfeld, Switzerland

5 Teaching the OADM

Every sensor is delivered with the factory setup (max. measuring range). The teach-in feature was designed
to choose a smaller range within the nominal measuring range for optimizing the resolution and linearity.
Output current, voltage and alarm output adapt to the new range. Two positions must be taught.

The first teach-in position aligns with 0 V (or 4 mA), the second position aligns with 10 V (or 20 mA)

These teach-in positions are always just at the border of the new range (inside the measuring range)

The sensor may be taught more than 10,000 times in its lifetime

The sensor can always be reset to the factory settings

The sensor may be taught with the teach button or via the external teach input

During the teach-in process, the red LED provides a feedback

The red LED on the back side of the sensor indicates “run” mode if an object is within the measuring

range.


Attention:
Within 5 minutes after power on, the sensor can be taught via the button or the teach-in wire. After 5 minutes,
the teach-in button will be locked preventing accidental adjustment. The teach-in wire is active all the time.


Example of a taught measuring range:



Example of a reverse taught measuring range:


30 mm

130 mm

0V / 4mA

Analog out

10V / 20 mA

Example
of a
taught
output
curve

LED

Standard output

curve

30 mm

130 mm

0V / 4mA

Analog out

10V / 20mA

Example of
a reversed
output
curve

LED

Standard output

curve

Advertising