10 technical data, Technical data – Baumer HMG 161 Benutzerhandbuch

Seite 40

Advertising
background image

37

Baumer_HMG161_II_DE-EN (13A1)

MB115 - 11055726

10

Technical data

10

Technical data

10.1

Technical data - electrical ratings

•

Voltage supply:

9...30 VDC

•

Consumption w/o load:

≤100 mA (per interface SSI)

≤250 mA (per interface bus)

•

Initializing time:

≤200 ms after power on

•

Interfaces:

SSI, Profibus-DPV0, CANopen®, DeviceNet

•

Function:

Multiturn

•

Transmission rate:

9.6...12000 kBaud (Profibus)

10...1000 kBaud (CANopen®)

125...500 kBaud (DeviceNet)

•

Profile conformity:

Profibus-DPV0

CANopen® CiA DSP 406 V 3.0

Device Profile Encoder V 1.0

•

Device adress:

Rotary switch in bus cover

•

Steps per turn:

8192 / 13 bit

•

Number of turns:

≤65536 / 16 bit

•

Additional output signals:

Square-wave TTL (RS422)

Square-wave HTL

•

Incremental output:

2048 pulses per revolution

•

Sensing method:

Optical

•

Code:

Gray (version SSI)

•

Code sequence:

CW default

•

Inputs:

SSI clock (version SSI)

•

Interference immunity:

EN 61000-6-2:2005

•

Emitted interference:

EN 61000-6-3:2007/A1:2011

•

Programmable parameters:

Depending on the selected absolute interface

•

Diagnostic function:

Position or parameter error

•

Status indicator:

DUO-LED integrated in bus cover

•

Approval:

CE, RoHS, UL approval / E256710